NOTE:
Ensure that the PHM is held parallel to the system board to prevent damaging the components.
2
Push the blue retention clips inward to allow the heat sink to drop into place.
3
Supporting the heat sink with one hand, use the Torx #T30 screwdriver and tighten the screws on the heat sink in the order below:
a
Partially tighten the first screw (approximately 3 turns).
b Tighten the second screw completely.
c
Return to the first screw and tighten it completely.
If the PHM slips off the blue retention clips when the screws are partially tightened, follow these steps to secure the PHM:
a
Loosen both the heat sink screws completely.
b
Lower the PHM on to the blue retention clips, follow the procedure described above in step 2.
c
Secure the PHM, follow the procedure described above in step 3.
NOTE:
The processor and heat sink module retention screws should not be tightened to more than 0.13 kgf-m (1.35 N.m or
12 in-lbf).
Figure 35. Installing a processor and heat sink module
Next steps
1
Install the air
shroud.
2
Follow the procedure listed in

M.2 SSD module

Removing the M.2 SSD module

Prerequisites
1
Follow the safety guidelines listed in
78
Installing and removing system components
After working inside your
system.
Safety
instructions.