Warranty Conditions - Calorex VPT Series Owners & Installation Manual

V-pac inverter heat pumps
Table of Contents

Advertisement

OWNER/INSTALLATION MANUAL

11.0 WARRANTY CONDITIONS

The following exclusions apply to e warranty given
by Dan erm Ltd. No claims will be accepted if:
1. The heat pump is installed in any way at is not in
accordance wi
e current procedures as defined
by Dan erm Ltd.
2. The heat pump has been worked upon or is
adjusted by anyone o er an a person au orised
to do so by Dan erm Ltd.
3. The heat pump is incorrectly sized for e
application.
4. The water flow rough e machine is outside e
specified limits.
5. The water pH level and/or chemical balance is
outside e following limits:
Acidity pH
Total Alkalinity, as CaCO3
Total Hardness, as CaCO3
Total Dissolved Solids
Maximum Salt Content
Free Chlorine Range
Free Chlorine Range
Super-chlorination
Bromine
Baquacil
Ozone
Maximum Copper Content ppm
Aquamatic Ionic Purifier
6. The heat pump has suffered frost damage.
7. The electrical supply is insu cient or in any way
incorrect.
30
pH
7.2 - 7.8
ppm
80 - 120
ppm
150 - 250
ppm
1000
ppm
35000
ppm
1 - 2 Domestic
ppm
3 - 6 Commercial
max
30ppm for 24 hrs
ppm
2 - 5
ppm
25 - 50
ppm
0.9 Max
1
ppm
2 Max
8. The fan amps and duct pressure are outside e
specified limits.
9. The air flow to and from e machine is outside e
specified limits.
If in doubt or if advice is required please contact
e Dan erm Group UK Service Department by
calling +44 (0)1621 856 611 (option 4) or email
service.department@dan erm.com
Please give MODEL NUMBER and SERIAL NUMBER
of your heat pump when making technical or service
enquiries. This will assist in correct diagnosis and ensure
service can be provided wi
e minimum delay.