Calorex C-PAC+ CPT6 ALY Owners & Installation Manual

Calorex C-PAC+ CPT6 ALY Owners & Installation Manual

Swimming pool heat pumps

Advertisement

C-PAC+ swimming pool heat pumps
CPT 6, 8, 12, 15, 20
Owner Installation Manual 1006905 Issue 2

Advertisement

Table of Contents
loading

Summary of Contents for Calorex C-PAC+ CPT6 ALY

  • Page 1 C-PAC+ swimming pool heat pumps CPT 6, 8, 12, 15, 20 Owner Installation Manual 1006905 Issue 2...
  • Page 2: Health And Safety Warning

    OWNER/INSTALLATION MANUAL HEALTH AND SAFETY WARNING This product contains electrical and rotational equipment. ONLY competent trained people should work on this device, and must be isolated electrically before removing access panels. This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction...
  • Page 3: Table Of Contents

    CONTENTS HEALTH AND SAFETY WARNING ���������������������������2 4�0 USING YOUR HEAT PUMP �������������������������������20 1�0 INTRODUCTION ��������������������������������������������������4 4�1 THE KEY PAD ������������������������������������������������20 1�1 FOREWORD �����������������������������������������������������4 4�2 OPERATING INSTRUCTIONS �����������������������21 1�2 WARNINGS ������������������������������������������������������4 5�0 TESTING �������������������������������������������������������������22 2�0 ABOUT YOUR HEAT PUMP �������������������������������8 5�1 HEAT PUMP MALFUNCTION ����������������������22 2�1 TRANSPORTATION ����������������������������������������8 5�2 PROTECTION CODES ����������������������������������23 2�2 ACCESSORIES �������������������������������������������������8...
  • Page 4: 1�0 Introduction

    OWNER/INSTALLATION MANUAL 1�0 INTRODUCTION 1�1 FOREWORD Thank you for choosing this product, which is designed for quiet and energy efficient operation. It is the ideal way to heat your pool in an environmentally friendly The WARNING sign denotes a hazard� It calls way.
  • Page 5 ACTIONS TO AVOID (OPERATION AND Do not use or store combustible gas or liquids near the HANDLING): heat pump. Check if there are any local regulations, which Be especially careful when handling the heat pump, you must comply to, when installing or storing not to cause any damage that may result in leakage of the heat pump�...
  • Page 6 OWNER/INSTALLATION MANUAL Installation must be carried out by competent people, Electric storms can damage electronic equipment. in accordance with this manual. Ideally the heat pump should be switched off at the mains. INSTALLATION: HEAT PUMP MALFUNCTION: Read the instructions before installation, use and maintenance.
  • Page 7 Do not use means to accelerate the defrosting The heat pump must be kept process or to clean, other than away from sources of fire or those recommended by the naked flames. manufacturer. The appliance shall be stored in a room without continuously The heat pump must be operating ignition sources installed in well ventilated...
  • Page 8: 2�0 About Your Heat Pump

    OWNER/INSTALLATION MANUAL 2�0 ABOUT YOUR HEAT PUMP 2�1 TRANSPORTATION Always keep the heat pump upright. Do not lift the heat pump by the water inlet or outlet connections� (If this is done the titanium heat exchanger inside the heat pump could be damaged). WATER WATER 2�2 ACCESSORIES...
  • Page 9: 2�3 Features

    2�3 FEATURES • Quick hot gas defrosting with 4-way valve. • High-efficiency full flow titanium heat exchanger. • High pressure and low pressure protection. • Soft start and wide voltage application. • Multi function operation. Can also be used for cool pools.
  • Page 10: 3�0 Installation

    OWNER/INSTALLATION MANUAL 3�0 INSTALLATION Installation must only be attempted by competent personnel 3�1 POSITIONING AND AIRFLOW Airflow - general principles The heat pump absorbs energy from the air drawn The heat pump must be positioned in a well through it. To function effectively the heat pump must ventilated area.
  • Page 11 Possible positions of a Calorex heat pump Calorex >250 cm Calorex* Wall Plant room Wall Calorex* >70 cm Suitable opening Calorex The red lines represent e air inlet area Required free areas to provide air flow to and from heat...
  • Page 12 OWNER/INSTALLATION MANUAL To comply with safety regulations regarding electrical installations in wet areas the heat pump must be installed at least 350cm away from the edge of the pool or spa. Swimming pool or spa 1006905 ISSUE 2...
  • Page 13: 3�2 Refrigerant Type And Installed

    3�2 REFRIGERANT TYPE AND INSTALLED LOCATION This heat pumps CPT6, CPT8, CPT12 and CPT15 All flammable refrigerants will not ignite if the contain R32, which is an environmentally friendly concentration level in a room stays below their lower refrigerant with a GWP (Global Warming Potential) of flammability limit (LFL).
  • Page 14: 3�3 Pool Water Circuit

    3�3 POOL WATER CIRCUIT Pool Aux heater Non return Sanitiser or (If fitted) valve chemical dosing device, (If fitted) Calorex Heat pump Anti return loop Condensate to be incorporated, water to To waste minimum height waste 100mm above heat pump outlet port (If sanitiser fitted)
  • Page 15: 3�4 Plumbing

    3�4 PLUMBING IMPORTANT Before installing the heat pump ensure the blanking disks are removed from the pool water in/out connections� These should drop out when the adaptors are unscrewed� 1. Ensure that bypass is installed and set to achieve the recommended flow rates stated in the data sheet.
  • Page 16: 3�6 Electrolytic Corrosion In Swimming

    OWNER/INSTALLATION MANUAL 3�6 ELECTROLYTIC CORROSION IN SWIMMING 3�7 ELECTRIC WIRING AND SUPPLY POOLS Electrolytic corrosion will occur when dissimilar metals All electrical work to be carried out in accordance with that are in contact with each other create a potential l.E.E.
  • Page 17: 3�8 Connecting The Heat Pump To The

    3�8 CONNECTING THE HEAT PUMP TO THE POWER SUPPLY Two cable The terminals for connecting entry points e heat pump to e power supply Undo e screws are behind is panel. Cable Entry point Remove Li lower Remove two screws panel away four screws and remove cover...
  • Page 18: 3�9 Pool Pump Synchronisation

    OWNER/INSTALLATION MANUAL 3�9 POOL PUMP SYNCHRONISATION TERMINALS P1 AND P2 For installations where the pool filter pump runs hours. If the pool does not need heating/cooling the continuously, these terminals do not need to be used. filter pump will be turned off after 5 minutes until the next sampling period, or the next timeclock “pump For installations where a timeclock controls the pool on”...
  • Page 19: 3�10 Remote On - Off Connection

    3�10 REMOTE ON - OFF CONNECTION For installation where the heat pump is to be turned The heat pump is supplied with a link wire in the on/off remotely. remote terminals, for use without a switch. When fitting a remote switch, remove the link wire. There is a pair of terminals available for connecting a switch, which are marked Remote on/off and are situated below the mains in terminals.
  • Page 20: 4�0 Using Your Heat Pump

    OWNER/INSTALLATION MANUAL 4�0 USING YOUR HEAT PUMP 4�1 THE KEY PAD Defrost mode Fan running Cooling mode Heating mode Auto mode SET IN ROOM OUT Ambient temperature. Current water inlet 88 88 (ROOM OUT) temperature.(SET IN) *Error codes show here Fault indicator Timer function Number of timers set...
  • Page 21: 4�2 Operating Instructions

    4�2 OPERATING INSTRUCTIONS IMPORTANT Remember that at start-up there is a 3 minute time delay before the heat pump starts a� Power On f� Timer setting Press the to power on. Press again to put The programmable timer allows for the heat pump to heat pump in standby mode.
  • Page 22: 5�0 Testing

    OWNER/INSTALLATION MANUAL 5�0 TESTING Inspect the heat pump before use • Check that the fan, air inlets and outlets are not • Check that the electric wiring conforms to the obstructed. electric wiring diagram and that the machine is earthed. •...
  • Page 23: 5�2 Protection Codes

    5�2 PROTECTION CODES These codes indicate machine stopping due to external circumstances� These are not faults with the heat pump� Display Reason Solution No Water flow through the heat pump Check water circuit and pool pump Low water flow indicated by more P6/P8 that 10°C difference in inlet and outlet Check water flow and pool pump...
  • Page 24: 6�0 Maintenance

    OWNER/INSTALLATION MANUAL 6�0 MAINTENANCE 7�0 TROUBLE SHOOTING COMMON FAULTS Isolate the power supply of the heat pump and wait 3 Minutes before cleaning, examination or repair� Requirements for service personnel Cover the heat pump body when not in use. Please clean this heat pump with household Any person who is involved with working on or detergents or clean water, NEVER use petroleum spirit, breaking into a refrigerant circuit should hold a current...
  • Page 25: 8�0 Datasheet

    8�0 DATASHEET MODEL UNITS CPT6 ALY CPT8 ALY CPT12 ALY CPT15 ALY CPT20 BLY PERFORMANCE CONDITION: Air 24°C/Water 26°C/RH 80% Heating capacity 7.51 8.92 13.46 16.9 23.1 Input current 12.1 12.3 6.31 6.45 6.63 6.31 5.01 PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70% Heating capacity 5.75 10.83...
  • Page 26: 9�0 Dimensions

    OWNER/INSTALLATION MANUAL 9�0 DIMENSIONS Pressure gauge Air inlet Water Outlet Air inlet Water Inlet Condenser drain down (for winterisation) CPT6 ALY CPT8 ALY CPT12 ALY 1130 CPT15 ALY 1130 CPT20 BLY 1299 1077 1006905 ISSUE 2...
  • Page 27 9�1 DIMENSIONS Water Outlet Air inlet Water Inlet Air inlet CPT6 ALY CPT8 ALY CPT12 ALY CPT15 ALY CPT20 BLY 1006905 ISSUE 2...
  • Page 28: 10�0 Winterisation Procedure

    OWNER/INSTALLATION MANUAL 10�0 WINTERISATION PROCEDURE WARNING. Isolate machine before opening! As heat pump embodies electrical and rotational equipment, it is recommended for your own safety that a competent person carries out the following procedure. (Drain Down Procedure) 4. Drain water from heat pump by: a) Drain valve if fitted.
  • Page 29: 11�0 Warranty Conditions

    11�0 WARRANTY CONDITIONS Where commissioning is provided in the UK and 6. The heat pump has suffered frost damage. Ireland, this must be carried out by factory trained and 7. The electrical supply is insufficient or in any way approved personnel. incorrect.