Warranty Conditions - Calorex PPT8 Installation Manual

Hide thumbs Also See for PPT8:
Table of Contents

Advertisement

Installation Manual
PPT8/12/16/22L/LY

13.0 Warranty Conditions

The following exclusions apply to the Warranty given by Calorex Heat Pumps Ltd. No claims will be ac-
cepted if : -
1. The heat pump is incorrectly sized for the application.
2. The heat pump is installed in any way that is not in accordance with the current procedures as defined
by Calorex Heat Pumps Ltd.
3. The heat pump has been worked upon or is adjusted by anyone other than a person authorised to do so
by Calorex Heat Pumps Ltd.
4. The air flow to and from the machine is outside the specified limits.
5. The water flow through the machine is outside the specified limits.
6. The water pH level and/or chemical balance is outside the following limits:-
Acidity pH
Total Alkalinity, as CaCO
Total Hardness, as CaCO
Total Dissolved Solids
Maximum Salt Content
Free Chlorine Range
Free Chlorine Range
Superchlorination
Bromine
Baquacil
Ozone
Maximum Copper Content
Aquamatic Ionic Purifier
7. The heat pump has suffered frost damage.
8. The electrical supply is insufficient or in anyway incorrect.
Calorex Heat Pumps Ltd. · The Causeway, Maldon, Essex CM9 4XD, UK · Tel: +44 (0)1621 857 171
3
3
Page 37
pH
7.2 - 7.8
ppm
80 - 120
ppm
150 - 250
ppm
1000
ppm
35,000
ppm
1 - 2 Domestic
ppm
3 - 6 Commercial
max
30ppm for 24 hrs
ppm
2 - 5
ppm
25 - 50
ppm
0.9 Max
ppm
1
ppm
2 Max