Installation; Positioning And Airflow - Calorex VPT Series Owners & Installation Manual

V-pac inverter heat pumps
Table of Contents

Advertisement

OWNER/INSTALLATION MANUAL

3.0 INSTALLATION

Installation must only be attempted by competent
personnel.

3.1 POSITIONING AND AIRFLOW

The heat pump must be positioned in a well
ventilated area. Minimum distances between e heat
pump and any obstructions are shown below.
• The heat pump must be fixed by M10 bolts to a
concrete base or mounting brackets. These must be
solid and fixed securely. Brackets must be corrosion
proof.
• Do not block inlet or outlet grilles.
10
500mm
500mm
Airflow - general principles
The heat pump absorbs energy from e air drawn
rough it. To function effectively e heat pump must
have access to e fresh air it needs.
• Air must not recirculate. The air leaving e heat
pump must not be sucked back into e inlet.
• Air must not be restricted. The air volume must not
be reduced.
• The minimum required distances shown below
must be provided to minimise e risk of air
recirculation or restriction and reduction in
performance. Fur er examples are shown on e
following page.
3000mm
500mm
1005759 ISSUE 3