Plumbing; Initial Checks - Calorex VPT Series Owners & Installation Manual

V-pac inverter heat pumps
Table of Contents

Advertisement

3.4 PLUMBING

IMPORTANT
Before installing e heat pump ensure e
blanking disks are removed from e pool water
in/out connections. These should drop out when
e adaptors are unscrewed.
1. Ensure at bypass is installed and set to achieve
e recommended flow rates stated in e data
sheet.
2. Ensure at e condensate drain kit supplied is
fixed and is drained to a drain or soak-away.
Water
out
3. Inlet and outlet pipework must be supported to
avoid excessive strain on e connections.
4. Water quality must be maintained. See warranty
conditions.
1005759 ISSUE 3
Start e filtration pump before e heat pump is
turned on and turn off e heat pump before e
Water
filtration pump. It is recommended to turn off e heat
in
pump prior to backwashing.
Before starting e heat pump, please check for
any leakage of water; and check/set e required
temperature on e controller, and en turn on.
In order to protect e components, e heat pump
incorporates time delays. When starting heating/cooling
starts. The heat pump runs for a minimum of 5
minutes. When e heat pump stops heating/cooling,
or is turned off by e user, e fan will continue to run
for one minute.
A er starting up, check for any error codes or abnormal
noise from e heat pump.
Supported pipework

3.5 INITIAL CHECKS

e fan will run for one minute before e compressor
15