Motion Sensor Settings
Table 10: Motion Sensor Settings
Field
Monitoring
No movement
sensitivity
No movement
timeout (seconds)
Tilt sensitivity
Tilt timeout
(seconds)
Webex Wireless Phone 840 and 860 Administration Guide for Cisco Unified Communications Manager
68
Field Type Or
Default
Choices
On
Off
Off
Disabled
Disabled
Level 1 (lowest)
Level 2
Level 2
Level 2
Level 2
Level 2
Level 7 (highest)
Integer 10–300
30
Disabled
Disabled
Level 1 (lowest)
Level 2
Level 2
Level 2
Level 2
Level 2
Level 7 (highest)
Integer 10–300
10
Cisco App Configuration
Description
Enables Emergency motion monitoring.
Enable this setting to allow any of the
motion settings to trigger an alarm.
Sets the degree of motionlessness or lack
of any type of movement of the phone to
trigger an alarm.
Level 1 is the least sensitive. An alarm
triggers a warning if the user is moving
some, but below the normal threshold.
Level 7 is the most sensitive. An alarm
triggers if the user is almost completely
still.
Sets the length of time in seconds that the
user would have to maintain the configured
degree of stillness (or a more severe
degree).
Sets the nonvertical position of the phone
that is required to trigger an alarm.
Level 1 is the least sensitive. An alarm
triggers if the user is nearly prone.
Level 7 is the most sensitive. An alarm
triggers if the user was leaning somewhat.
Sets the length of time in seconds that the
user would have to maintain the configured
degree of tilt (or a more severe degree).

Advertisement