Directions for the user
To change the language in the control panel:
- Switch from the base display by pressing the Menu button
(Menu) to advance to the Main menu
- When the main menu opens, the marker is placed at Language
- Press the Select button
- Select the language with the  buttons and press the Set
button
- You can return to the base display if you wait a moment or if you
press the Return button enough times
To set the time and the weekday:
The display shows the time and the weekday. If required, this
function can be disabled in the Installation and Service menu.
- For example, press the right-hand button once to activate the
control panel.
- Immediately press the right-hand Menu button once more to
return to the Main Menu
- Use the  buttons to change to the Clock image
- Press in the right-hand button Select to switch to the Clock
menu
- Use the  buttons to change to the Clock image
- Press in the right-hand Select button to switch to the Time
menu
- Set the hours with the  buttons
- Switch to setting of minutes with the -button- Set minutes
with the  buttons
- Confirm the time by pressing the right-hand buttonSet
- The display returns to show Clock
- Use the  buttons in order to switch to Weekday and press
Select
- Use the + and – buttons to advance to the appropriate weekday
- Confirm the weekday by pressing the Set button
- You can return to the Base display if you wait a moment or if
you press the Return button enough times
To set reheating:
The reheating function is factory-preset for the discharge of air at
a temperature of 17 °C into the room.
N.B.! Reheating cannot be used simultaneously with
cooling of the air in the summertime. The Summer night
Cooling function must be shut-off before reheating can
be enabled.
- Switch from the base display by pressing the Menu button to
advance to the Main menu
- Select Reheat and press Select
- In the Heating equipment menu, select the option On
- Confirm and return to the Main menu
- Switch to the Main menu point Temperature and press
Select
- The temperature menu allows you to change the Supply air
temperature [13–20 °C]
Summer night cooling:
The Summer night cooling can be used if the temperature of the
supply air exceeds the temperature of the outside air. The function
can only be used if the temperature is higher than 13 °C. The
lower set value of the temperature of the indoor air, the earlier
the function starts. The airing effect can be changed with the fan
speeds belonging to the function.
N.B.! Cooling of the air in the summertime cannot be used
simultaneously with the reheating. The Summer night
cooling function must be shut-off before the reheating can
be enabled.
- Go from the base display by pressing the Menu button to
advance to the Main menu
- Switch to Summer night cooling and press Select
- In the Summer night cooling menu select the alternative On
- Switch to Start temperature
- Specify at Start temperature the desired indoor temperature.
This enables the function. The factory setting is 21 °C.
- In the Summer night cooling image, switch to Fan speed
and press Select
- In the Fan speed menu you can change the fan speeds for the
Summer night cooling. [No change/Away/At Home/ Boost/Cool-
ing]. Because it is factory preset, the fan speed is not changed,
but the value set by the user applies.
Base display:
The display shows the fan speed selected for the ventilation unit
- In the Away/At Home/Boost settings = Base display 1
- Stepless = Base display 2
- Switch from the base display by pressing the Menu button to
advance to the Main menu
- Switch to Base display and press Select
- Enable either Base display 1 or Base display 2
To switch off the unit:
When the ventilation unit is switched off from the control panel, the
fans stop and the air heater is switched off. The circuit card is how-
ever still energised and the settings are preserved in the memory.
- Switch from the base display by pressing the Menu button to
advance to the Main menu
- Switch to Shut-off and press Select
- The display will show Shut-off? and you can confirm by press-
ing the right-hand button.
Fireplace switch function:
The quick selection button of the fireplace function is available as
standard on the control panel. The fireplace function temporarily
generates positive pressure in the home, making it easier to light
a fire in the fireplace. The fireplace function lasts 10 minutes. In
homes without fireplace the function can be disabled from the
control panel as described below.
- Switch from the base display by pressing the Menu button to
advance to the Main menu
- Switch to Fireplace function and press Select
- In the Fireplace function menu, set Off