Available languages

5. Connect the ventilation unit to the mains electric supply with its
power plug. The main switch of the ventilation unit can consist of its
power plug inserted into or removed from the mains supply outlet
(note that it should be easy to pull out) or an extra mains power
switch installed across the power supply cord. A door switch installed
in the door of the unit serves as its service switch.
6. Mount the ILTO Premium control panel in an equipment cubicle
located in a dry space. The control cable should be mounted in a
conduit having a diameter of at least 20 mm.
Loosen the display of the control panel by pressing in the locking tabs.
Use a screwdriver or the like for this purpose. The control cable can
be connected to any of the connections behind the display. Secure
the display by means of screws to the cubicle and fasten the frame
by pressing it to engage in the locking tabs.
N.B.! The cable must not be lengthened with an extension.
WARNING: It is absolutely forbidden to use the ventilation
system while the building is under construction or if dust-
raising work is in progress.
The ducts should be covered with covers to prevent impuri-
ties from entering them.
Removal of the panel from the ILTO Premium
control unit.
Connection of the control cable.
Fitting the panel cover onto the ILTO Premium control
unit. First place the upper edge of the cover in place
and then press the cover to secure it.
Connection of control panels when two panels are used.