G
B
POINT B
- sETTINGs
DIP 1
MOTOr rOTATION DIrECTION CHECK (see Point C)
DIP 2
PrOGrAMMING (see Point D)
DIP 2-1 PrOGrAMMING Of PEDEsTrIAN OPENING (see Point E)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Radio receiver STEP BY STEP
OFF - Radio receiver AUTOMATIC
DIP 5
ON - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
OFF - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
DIP 6
ON - Photocells active only in closing
OFF - Photocells always active
DIP 7
ON - Encoder enabled for PLUS operator
OFF - Encoder disabled
DIP 8
ON - Blinker pre-flashing
OFF - Blinker normal flashing
DIP 9
ON - Low speed in approaching DISABLED
OFF - Low speed in approaching ENABLED
DIP 10 ON - Electronic brake ENABLED (HARD brake, only for FAST operators)
OFF - Electronic brake DISABLED (SOFT brake, only for FAST
operators)
DIP 11 ON - Gradual start ENABLED
OFF - Gradual start DISABLED
DIP 12 ON - Safety strip self test ENABLED
OFF - Safety strip self test DISABLED
DIP 13 ON - Motor operation control by external power relays (only for S1/R2
and S1/R4 control boards). Encoder, low speed in approaching,
gradual start and electronic brake features, low speed and torque
regulator will be automatically disabled regardless their dip-
switches and trimmers position.
OFF - Standard motor operation control without power relays
DIP 14 ON
DIP 15 OFF
DIP 16 ON
DIP 17 ON - close command after the transit through the photocell ENABLED
OFF - close command after the transit through the photocell DISABLED
DIP 18 ON - Working with motors 120V 60Hz
Off - Working with motors 230V 50-60Hz
LED WArNINGs
DL1 - programming activated (red)
DL2 - stop contact NC (red)
DL3 - open limit-switch contact (red)
DL4 - close limit-switch contact (red)
DL5 - photocell contact (NC) (red)
DL6 - gate opening (green)
DL7 - gate closing (red)
DL8 - safety strip contact (NC) (red)
DL9 - Encoder output state
fUsEs
F1 T100mA
Fuse for accessories protection
F2 T5A
Fuse for motor windings protection
rELAYs AND MOTOr CONTrOL
K1 => Opening command
K2 => Closing command
K3 => Flashing light command
Q5 => TRIAC - Motor command in opening and closing
TOrQUE =>Tr2 - Electronic regulator for motor torque
Power can be controlled by rotating the TORQUE trimmer – this changes the
output voltage on motor ends (more power is delivered to the motor by rotating the
trimmer clockwise).
Actually, the motor is always turned on at full power regardless the trimmer position
(to guarantee the starting in all the condition) and, then, after 3seconds, the torque
control is activated.
LOW sPEED =>Tr1 - Electronic regulator for low speed on approach
If DIP9 is turned OFF, the low speed on approach can be controlled by rotating
the LOW SPEED trimmer. The low speed is activated when the gate is 0.50-0.60
meters away from the complete closed or open position.
ELECTrONIC BrAKE (for fAsT operators)
If DIP10 is turned ON, a HARD electronic brake will be active.
If DIP10 is turned OFF, a SOFT electronic brake will be active.
GrADUAL sTArT
If DIP11 is turned ON, a gradual movement will be enabled for 1second upon
each starting.
In case of an obstacle is detected by any safety inputs (photocell, safety strip or
encoder), the gradual start is bypassed for the time being to guarantee a more
prompt and safe reaction.
POINT C
- MOTOr rOTATION DIrECTION CHECK
This operation is meant to help the installer during the installation and for further
future controls.
1 - Unlock the operator with the Manual Release, slide the leaf open about halfway
and lock the operator again.
2 - Turn DIP1 to ON position, LED DL1 starts blinking
3 - Press and hold the PrOG.Button, the gate will open or close. Release the
button and the gate will stop. Press and hold again, the gate will move in the
opposite direction.
The S1 control board has two movement leds
- DL6 the GREEN led for OPENING
- DL7 the RED led for CLOSING
When you press and hold the PROG.Button, if the gate opens with the green
led on then you may proceed to step 4.
If the gate moves in the wrong direction compared with the movement leds:
- turn OFF the main AC power
- reverse the V and W motor cables position (the blue motor cable must be
always in the U position)
- reverse the limit switch wires marked LSO and LSC
- turn ON the main AC power and check again the motor direction
4 - After 2 seconds motor starting and for the next 6 seconds motor working,
the torque control is automatically activated. Set the motor torque by the
TORQUE Trimmer which varies the output voltage to the head of the motor
(turn clockwise to increase torque).
5 - After other 6 seconds motor working, the low speed control is automatically
activated (DIP9 OFF). Set the motor low speed by the LOW SPEED Trimmer to
select the gate leaf low speed in approaching.
6 - Press and hold the PROG.Button to close completely the gate. Turn DIP1 to
OFF, the RED led DL1 will stop blinking.
During Point C procedure, safety devices (photocells and safety strip), stop
button and encoder input are not active.
(#) In Point D and Point E procedures, all of them will be active, so they must be
properly installed and connected to the control board. Any changing of the safety
devices input state, will stop the Point D and Point E procedure that must be
repeated from the beginning.
POINT D
- PrOGrAMMING (#)
THE DIP7 MUST BE TURNED ON DURING THE PROGRAMMING PROCEDURES.
1 - Procedure must be carried out with closed gate and closing limit switch engaged
(necessary).
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PrOG.Button, motor opens.
4 - Once reached the open position, the open limit switch will cut out motor and the
gate travelling will be stored. The gap of time between now (stop of motor) and
the next pressing of the PROG.Button (see step 5 below) will be then stored as
waiting time for Automatic Closing feature.
5 - Press PrOG.Button, gate closes and the Automatic Closing time is stored (see
DIP3 function to enable or disable the Automatic Closing feature).
6 - The LED DL1 will turn OFF, signalling exit from the Point D procedure.
Closing of the gate will be carried out at normal speed and only on approaching
total closing at low speed (depending on the adjustment of LOW SPEED
trimmer).
7 - When the gate leaf reaches the close limit switch plate, the motor stops.
8 - Turn DIP2 to Off position.
POINT E
- PrOGrAMMING Of PEDEsTrIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly
4 - Press the pedestrian pushbutton PED.Button, the gate opens
5 - When the gate leaf is opened enough for the pedestrian crossing, press the
pedestrian pushbutton PED.Button to stop the travel (thus defining the opening
stroke of the motor). The gap of time between now (stop of the motor) and the
next pressing of the PROG.Button (see step 6 below) will be stored as waiting
time for Pedestrian Automatic Closing feature.
6 - Press the pedestrian pushbutton PED.Button, gate closes and the
30
30