Viessmann Vitoligno 300-P Service Instructions For Contractors page 62

Pellet boiler
Table of Contents

Advertisement

Codes
Code 2
(cont.)
Coding in the delivered condition
90:128
Time constant for calcu-
lating adjusted outside
temperature 21.3 h
91:0
Connection at terminals 1
and 2 in plug aVD disa-
bled (external heating
program changeover)
(see page 114)
94:0
Do not adjust
95:0
Without Vitocom 100
96:0
Do not adjust
97:0
With LON communication
module:
The outside temperature
of the sensor connected
to the control unit is only
utilised internally
98:1
Viessmann system num-
ber (in conjunction with
monitoring several sys-
tems via Vitocom 300)
62
Possible change
90:1
Fast (low values) or slow
to
(high values) matching of
90:199
the flow temperature, sub-
ject to the set value when
the outside temperature
changes;
1 step ≙ 10 min
91:1
Contact affects the follow-
ing heating circuits:
Heating circuit 1
91:2
Heating circuit 2
91:3
Heating circuits 1 and 2
95:1
With Vitocom 100;
will be recognised auto-
matically
97:1
The control unit receives
the outside temperature
from the LON user
97:1
The control unit transmits
the outside temperature
from the LON users
98:1
System number adjustable
to
from 1 to 5
98:5