Viessmann Vitoligno 300-P Service Instructions For Contractors page 68

Pellet boiler
Table of Contents

Advertisement

Codes
Code 2
(cont.)
Coding in the delivered condition
E1:1
With remote control:
Set day temperature is
adjustable at the remote
control unit from 10 to
30 °C
E2:50
With remote control:
No display correction of
the actual room tempera-
ture
EXT:20
Coding "AA:2" must be
selected:
Minimum mixer position
when reducing output by
10%
F1:0
Screed function disabled F1:1
F2:8
Time limit for party mode
8 h or external operating
mode changeover via
key
Temperature limit for ter-
F8:−5
minating the reduced
mode -5 ºC, see example
on page 111.
Observe the setting of
coding address "A3"
Temperature limit for rais-
F9:−14
ing the reduced set room
temperature −14 ºC, see
example on page 111
Party mode ends automatically in the "Heating and DHW" program, when the
*1
system changes over to operation with standard room temperature.
68
*1
Possible change
E1:0
Set day temperature
adjustable from 3 to 23 °C
E1:2
Set day temperature
adjustable from 17 to
37 °C
E2:0
Display correction –5 K
to
to
E2:49
Display correction –0.1 K
E2:51
Display correction +0.1 K
to
to
E2:99
Display correction +4.9 K
EXT:0
Value adjustable from 0 to
to
100%;
1 step ≙ 0.5%
EXT:200
Screed drying function
to
adjustable in accordance
F1:6
with 6 optional tempera-
ture/time profiles (see
page 115)
F2:0
No time limit for party
mode
F2:1
Time limit adjustable from 1
to
to 12 h
F2:12
F8:+10
Temperature limit adjusta-
ble from +10 to −60 °C
to
F8:−60
Function disabled
F8:−61
F9:+10
Temperature limit adjusta-
ble from +10 to −60 °C
to
F9:−60
*1
*1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vl3b

Table of Contents