Viessmann Vitoligno 300-P Service Instructions For Contractors page 52

Pellet boiler
Table of Contents

Advertisement

Codes
Code 2
(cont.)
Parameter
address 17:...
0
1
2
3
4
5
Coding in the delivered condition
21:0
No hours run interval for
burner service
22:0
No fuel consumption
no metering
23:0
No time interval for
burner service selected
24:0
The service display is
reset
26:...
Enable only if a pellet
sensor is installed in the
pellet storage room/pellet
silo (with plug aNG)
2F:100
Correction factor pellet
consumption 100%
52
Supply system
Vacuum supply systems with room discharge from the storage
room
Auger supply systems with room discharge from the storage
room
Pellet supply from the pellet hopper (intermediate container)
Vacuum supply system from the pellet silo
Auger supply system from the pellet silo
Vacuum supply system with mole
Possible change
21:1
The number of hours run
to
before the burner should
21:100
be serviced is adjustable
from 100 to 10000 h;
1 step ≙ 100 h
22:1
Input of 0.1 to 25.5 t;
1 step ≙ 0.1 t
to
22:255
23:1
Interval adjustable from 1
to
to 24 months
23:24
24:1
Service display (address
set automatically)
26:0
No message "Refill
store"
26:1
Message "Refill store"
active
2F:70
Correction factor adjusta-
to
ble from 70 to 130%.
2F:130
Calculation of the amount
of pellets with the charge
auger constantly ON. This
value can be corrected with
this factor.