Viessmann Vitoligno 300-P Service Instructions For Contractors page 51

Pellet boiler
Table of Contents

Advertisement

Code 2
(cont.)
9. d
Overview
Coding
Coding in the delivered condition
02:0
Output 52 M1 not used
03:0
Output 52 M2 not used
04:0
Do not adjust
05:0
Do not adjust
06:...
Maximum boiler water
temperature limit
Delivered condition
defaulted by the boiler
coding card
08:0
Central fault message
connection at plug gÖ:
17:...
Delivered condition
defaulted by the config-
ured supply system (see
chapter "Configuring the
supply system")
to confirm.
In the display
"Accepted" appears
briefly.
10. Exit service menu.
Possible change
02:1
Output 52 M1 controls the
mixer of heating circuit
HC1; automatic recogni-
tion
03:1
Output 52 M2 controls the
mixer of heating circuit
HC2; automatic recogni-
tion
03:2
Output 52 M2 used for the
solar control unit; auto-
matic recognition
06:...
Subject to boiler output
(defaulted by the boiler
coding card)
08:1
Soft start connection at
plug gÖ (see page 113)
17:0
For supply systems, see
to
the following table (see
17:5
also page 11)
Codes
51