CHAPTER 4 – TRANSPORTATION, STORAGE AND DISPOSAL
4.4.3 Using a forklift (only ACS2000 with 1 MVA
References
output power)
Only transport the cabinet with the short side
4-2 Recommended
forklift position
facing the driving direction.
When transporting the drive cabinet, the rec-
4-3 Using one pallet truck
ommended position of the forklift is on the
right short side of the cabinet (4-2). This is the
cabinet side with the heaviest drive compo-
nents.
Use forks with sufficient length to ensure stable
transportation and to prevent tipping.
When the forklift is positioned on the left
(4-2:
cabinet.
When the forklift is positioned on the right
(4-2:
indicated by the
Insert the fork fully into the cabinet's forklift
pockets.
1
4-2
1), the forks must be at least as long as the
2), the forks must be at least as long as
arrow.
2
4.4.4 Using hand pallet trucks
Choose the load capacity and the fork length of
the pallet truck according to the following
table.
Transformer
Length (m)
Weight (kg)
1.6
1.9
2.2
2.4
2.6
Place the pallet truck on the left or on the right
of the cabinet.
Insert the forks fully into the cabinet's forklift
pockets.
3
4-3
Drive
Length (m)
Weight (kg)
1650
1.7
1500
3070
2.2
1800
4800
2.5
2100
5600
2.5
2240
6100
-