The Full Duplex Configuration Screen - Cabletron Systems DELHF-UA User Manual

Digital fddi modular interface
Table of Contents

Advertisement

The Full Duplex Configuration Screen

Treq
This field displays the Token Rotation Time (TRT) of the DELHF-UA.
Tneg
This field displays the negotiated token rotation time (in milliseconds)
that the stations on the ring established through the token claiming
process.
Tnotify
This field displays the interval (in seconds) at which the DELHF-UA
transmits Neighbor Information Frames (NIFs). The DELHF-UA uses
NIFs to periodically announce its address and basic station description. To
change the DELHF-UA Tnotify period from the default thirty seconds,
perform the following steps:
1. Use the arrow keys to highlight the Tnotify field.
2. Enter a value between 2 and 30.
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
The DELHF-UA now sends NIFs at the new interval.
SAVE
This command saves all configuration changes to memory.
3.9
THE FULL DUPLEX CONFIGURATION SCREEN
To access the Full Duplex Configuration screen from the DELHF-UA
Setup screen, use the arrow keys to highlight the Full Duplex
Configuration menu item and press ENTER. The Full Duplex
Configuration screen, Figure 3-14, displays.
DELHF-UA User's Guide
3-25