Cabletron Systems SSIM-R2-02 Installation And User Manual

Interface module

Advertisement

Quick Links

SSIM-R2-02/SSIM-R8-02
High Speed Token Ring
SmartStack Interface Modules
Installation
and
User Guide

Advertisement

Table of Contents
loading

Summary of Contents for Cabletron Systems SSIM-R2-02

  • Page 1 SSIM-R2-02/SSIM-R8-02 High Speed Token Ring SmartStack Interface Modules Installation User Guide...
  • Page 2 Notice Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
  • Page 3: Fcc Notice

    FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 4: Declaration Of Conformity

    Declaration of Conformity Application of Council Directive(s): 89/336/EEC European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC Equipment Type/Environment: Networking Equipment, for use We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with this notice conforms to the above directives.
  • Page 5 Notice...
  • Page 6: Table Of Contents

    ......22 ..... . . 31 SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 7 Table 5. Virtual Port Configuration: Maximum Frame Size ..19 Table 6. Config Loss Values ..... . . 26 SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 8: Introduction

    1. Introduction The SmartStack SSIM-R2-02 and SmartStack SSIM-R8-02 provide two ports of 100 Mbps High-Speed Token Ring for the SmartStack STS16-20RM Token Ring switch. Designed for high performance and low latency, these modules provide seamless integration between legacy Token Ring networks and HSTR servers or an HSTR backbone.
  • Page 9 The SSIM-R2-02 and SSIM-R8-02 conform to the IEEE 802.5t standard for 100 Mbps High-Speed Token Ring, and implement the standard DTR MAC protocol. An HSTR port can connect to a standard HSTR adapter or it can act as a trunk port and carry traffic from up to 63 VLANs configured in the switch.
  • Page 10: Installation

    2. Installation This chapter describes how to install, connect, and start using the SSIM-R2-02 or SSIM-R8-02. The following main topics are covered: • Package Contents • Installation Procedure • Hardware Installation • Software Installation • Cabling • LEDs • Power-On Self Test •...
  • Page 11: Hardware Installation

    9 as well as Chapter 3, “Console Configuration”. Hardware Installation To install the SSIM-R2-02 and SSIM-R8-02 in a SmartStack STS16-20RM or STS16-20FRM switch: 1. Power off the base switch by unplugging the power cord from the power outlet.
  • Page 12: Figure 2. Removing The Expansion Slot Cover

    Figure 3. Inserting the Module 5. Secure the SSIM-Rx-02 with the two attached thumb screws. 6. Reapply power to the switch. Installation SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 13: Software Installation

    7. Select HSTR Firmware Download Filename and type the filename of the software image to download. 8. Select Execute HSTR Image Network Download to start the download. While the software is transferred over the network, the console will display SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Installation...
  • Page 14: Serial Download

    SmartStack SSIM-R2-02 2-port High-Speed Token Ring SSIM (UTP5) The UTP module uses standard UTP Category 5 copper cables. The maximum cable length is 100 m (328 feet). Installation Now transferring to HSTR SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 15: Leds

    Port or Station mode. Refer to Chapter 3, “Console Configuration” for details on port mode configuration. The SSIM-R2-02 also supports IBM type 1 STP copper cables (150 Ohm), which have a maximum length of 100m (328 feet). To use an STP cable, then balluns with an RJ-45 connector are required.
  • Page 16: Power-On Self Test

    If the test reveals a problem, at the end of the test the DIAG LED will turn off. Messages in the message log or on the console will describe the problem. Configuration The are two ways to manage SSIM-R2-02 and SSIM-R8-02: • From the switch console, via Telnet or directly with a VT100 terminal emulator on the RS-232 port •...
  • Page 17: Default Configuration

    This configuration is suitable for connecting both HSTR adapters and other HSTR switch ports to the default CRF. If more advanced configurations are required, refer to Chapter 3, “Console Configuration” for details. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Installation...
  • Page 18: Console Configuration

    3. Console Configuration This chapter explains how to view and edit the configuration of the SSIM-R2-02 and SSIM-R8-02 using a VT100 terminal emulator attached directly to a SmartStack STS16-20RM switch. The SSIM-Rx-02 configuration can also be modified from a remote VT100 console via a Telnet session. Connecting a network management console is explained in the manual supplied with the SmartStack STS16-20RM switch.
  • Page 19: Introduction

    Each ordinary Token Ring port is assigned to a specific CRF, which also determines which VLAN it belongs to. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Console Configuration...
  • Page 20: Hstr Virtual Ports And Vlan Tagging

    This follows from the nature of VLAN tagging. It would not be possible to distinguish frames from two virtual ports in the same VLAN, since they would have the same VLAN identifier. Console Configuration SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 21: Ring Number Restriction

    If you are administering switches in a stack, many of the console screens will prompt for a box number. Enter the number of the box you want to administer to continue. The box that you are physically connected to is highlighted. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Console Configuration...
  • Page 22: Navigating Within The Menus

    Configure the HSTR port, in particular the operation mode. • Configure the virtual ports, in particular the tagging mode. The relevant configuration menus are described in the port configuration sections. Console Configuration SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 23: Port Configuration - Hstr Ports

    Display only. Shows the current status of the port. Can be one of the following: Value Auto Disabled Down Table 3. HSTR Port Configuration: Status Values SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Meaning The port has been auto disabled. The port has been disabled and the MAC protocol is disconnected.
  • Page 24 The port has been disabled and the MAC protocol is disconnecting. The MAC protocol has disconnected, but is actively trying to connect again. The disconnect reason might be a wire fault or configuration change. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 25: Virtual Port Configuration

    Waiting for port up Forwarding Table 4. Virtual Port Configuration: Status Values SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Meaning The port or virtual port is disabled. The virtual port is waiting for the port to come up.
  • Page 26: Table 5. Virtual Port Configuration: Maximum Frame Size

    Range: 0 to 5000 frame/sec or Disabled Default: Disabled. Console Configuration Meaning The virtual port is currently down because the port is temporary down. Actual HSTR frame size 1558 4556 9246 18202 SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide LF bits...
  • Page 27 Range 1 to 9999 minutes or 0 (for disabled). Default: 5 minutes. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Console Configuration...
  • Page 28: Statistics

    A wide range of statistics is available for the SmartStack STS16-20RM Token Ring switch. The following topics are discussed in this chapter: • Statistics Menu • Port Status • Port Statistics • General Statistics • Virtual Port Statistics • 802.5 MAC Information Statistics SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 29: Statistics Menu

    Port Status—includes SmartStack SSIM-Rx-02 virtual ports. • Port Statistics—includes additional counters for HSTR ports. • Address Tables—includes addresses learned from HSTR ports. • Message Log Information—includes messages generated by the module. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Statistics...
  • Page 30: Port Status

    For ordinary Token Ring ports, this is the enabled and inserted status. This does not apply to virtual ports on an HSTR port. Instead the current state of the virtual port is displayed. Refer to the description of virtual port configuration for details. Statistics SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 31: Port Statistics

    When Port Statistics is selected and the port number of an HSTR port is entered, the following menu appears: The available information is discussed in “General Statistics”, “802.5 Statistics”, and “Virtual Port Statistics” sections. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Statistics...
  • Page 32: General Statistics

    NSR, SRF, STE, and ARE frames. For received frames it is also subdivided into unicast, broadcast and multicast frames. All are explained later in this table. Statistics SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 33: Table 6. Config Loss Values

    Lobe Test Fail Heart Beat Table 6. Config Loss Values SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide The port was closed due to a wire fault, perhaps because the cable was removed. The lobe test failed during the recovery after a beacon condition.
  • Page 34 The port was closed after receiving a MAC frame with a source address different from the stored Upstream Neighbor address. The port was closed due to a MAC TXI protocol error. The port has never failed. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 35 Frame Too Large The frame was larger than the maximum frame size, configured for the virtual port. Refer to the table of maximum frame sizes in the description of virtual- port configuration. SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Statistics...
  • Page 36 (because the spanning tree protocol detected multiple parallel paths) or transient (during network topology changes). • Filtered By DSAP Filter A frame was discarded because of a protocol (DSAP or protocol type) filter. Statistics SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 37: Virtual Port Statistics

    The receiver on the other end will therefore count these frames as RX aborts. Virtual Port Statistics When Virtual Port Statistics is selected from the HSTR Port Statistics menu for an HSTR port, following screen appears for the selected port: SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Statistics...
  • Page 38: 802.5 Statistics

    Token Ring MAC layer protocol is displayed. The information on this menu is similar to that for ordinary Token Ring ports. Refer to the SmartStack STS16-20RM Token Ring Switch Installation and User Guide for details. Statistics SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 39 SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Statistics...
  • Page 40: Getting In Touch With Technical Support

    The device history (i.e., have you returned the device before, is this a recurring problem, etc.) • Any previous Return Material Authorization (RMA) numbers Getting in Touch with Technical Support http://www.cabletron.com/ (603) 332-9400 support@cabletron.com ftp://ftp.cabletron.com/ anonymous your email address SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 41: Problem Report Form

    Operating system: Network OS: Driver name: Driver version: Company: ____________________________ Name: ______________________ Address: __________________________________________________________ Country: _______________________ Phone/Fax: ________________________ E-mail: _____________________ SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Switch Information Switch Configuration Adapter Information Getting in Touch with Technical Support...
  • Page 42: Problem Description

    Problem Description Network Installation Sketch Getting in Touch with Technical Support SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 43 SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Getting in Touch with Technical Support...
  • Page 44: Appendix A. Abbreviations

    Internet Protocol Local Area Network Light Emitting Diode Logical Link Control Media Access Control Mbps MegaBit Per Second Multi Mode Fiber Maximum Transmission Unit Non-Source Routed NVRAM Non-Volatile RAM Random Access Memory SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide...
  • Page 45 SSAP Source SAP SSIM SmartStack Interface Module Spanning Tree Explorer Tag Control Information TFTP Trivial File Transfer Protocol Token Ring Transmit Data Transmit Immediate Unshielded Twisted Pair VLAN Virtual LAN SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Abbreviations...
  • Page 46 “dots” using the menus virtual ports statistics VLANs SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide index-1...
  • Page 47 SSIM-R2-02/SSIM-R8-02 HSTR SmartStack Interface Modules Installation and User Guide Index...
  • Page 48 * 710001813*...