Cabletron Systems THN-MIM Installation Manual

Coaxial media interface module

Advertisement

Quick Links

COAXIAL MEDIA INTERFACE
MODULE (THN-MIM)

INSTALLATION GUIDE

The Complete Networking Solution™
CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505

Advertisement

Table of Contents
loading

Summary of Contents for Cabletron Systems THN-MIM

  • Page 1: Installation Guide

    COAXIAL MEDIA INTERFACE MODULE (THN-MIM) INSTALLATION GUIDE The Complete Networking Solution™ CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505...
  • Page 2 P.O. Box 5005, Rochester, NH 03867-0505 All Rights Reserved Printed in the United States of America Order Number: 9030034-02 February 92 MMAC, MMAC-8, THN-MIM, LAN-MD, TMS-3, and, Remote LANVIEW are trademarks of Cabletron Systems, Inc. LANVIEW and SPECTRUM are registered trademarks of Cabletron Systems, Inc.
  • Page 3: Fcc Notice

    NOTICE FCC NOTICE This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules.
  • Page 4: Table Of Contents

    CHAPTER 1 INTRODUCTION 1.1 INTRODUCTION ... 1-1 1.2 USING THIS MANUAL ... 1-2 1.3 SPECIFICATIONS ... 1-2 1.4 RELATED USER MANUALS ... 1-4 CHAPTER 2 INSTALLATION 2.1 INTRODUCTION ... 2-1 2.2 NETWORK DESIGN GUIDELINES... 2-1 2.2.1 Thin-net Segments... 2-1 2.2.2 Thin-net Segments (THN-MIM7593 only) ... 2-2 2.2.3 Thick-net Segments ...
  • Page 5 CONTENTS...
  • Page 6: Chapter 1 Introduction

    Either thick or thin Ethernet cable can be connected to the THN-MIM. Thin-net cable segments, using 50 ohm Ethernet type cable, can be connected directly to the module. Each of these segments can be up to 185 meters in length and can support up to 29 users.
  • Page 7: Using This Manual

    Each of these segments supports one device. The entire THN-MIM or each port on the MIM can be controlled via the IRM in your MMAC. The IRM can be accessed directly through a...
  • Page 8 50 ohm terminator in the port. Each segment connector shield is internally connected to earth ground by the THN-MIM. This eliminates the need for grounding the segments connected to the BNC ports. Indicates that the port is connected to the network.
  • Page 9: Related User Manuals

    SAFETY WARNING: It is the responsibility of the person who sells the system of which the THN-MIM will be a part, to ensure that the total system meets allowed limits of conducted and radiated emissions. Designed in accordance with UL478, UL910, NEC 725-2(b), CSA, IEC, TUV, VDE class A.
  • Page 10: Chapter 2 Installation

    Connection to earth ground at more than one point on the segment may allow for the occurrence of dangerous ground currents. The BNC ports of the THN-MIM are connected to earth ground. This eliminates the need of grounding the thin-net segments connected to the module.
  • Page 11: Thin-Net Segments (Thn-Mim7593 Only)

    INSTALLATION Since the ports on the module are internally terminated, the end of the segment that will be connected to the module will not be a tee connector or terminator. 2.2.2 Thin-net Segments (THN-MIM7593 only) The following network design guideline must be followed when connecting 75 or 93 ohm coaxial cable segments to the THN-MIM7593.
  • Page 12: Thick-Net Segments

    Connection to earth ground at more than one point on the segment may allow for the occurrence of dangerous ground currents. The BNC ports of the THN-MIM are connected to earth ground. This eliminates the need for grounding a thick-net segment connected to the module.
  • Page 13: Installation Checkout

    4. Slide the module into the MMAC card cage. 5. Secure the module to the MMAC by turning the knurled knobs. CAUTION: Be sure the THN-MIM is firmly attached to the MMAC by turning the knurled knobs. Failure to do so may result in improper operation.
  • Page 14: Introduction

    3.2 INSTALLATION CHECK-OUT This section contains procedures to test that the physical layer of the network and a coaxial segment connected to the THN-MIM are operating properly. This section also contains procedures to check that the physical layer of the network is operating properly. An Ethernet node tester that will generate valid data packets, such as Cabletron Systems LAN-MD, is required for this procedure.
  • Page 15: Using Lanview

    The packets will be received from and sent back to the LAN-MD acting as the SERVER. When the applicable segment(s) connected to the THN-MIM have successfully completed these tests, the segments are ready for normal operation. If any failures were noted, please contact Cabletron Systems Technical Support.