Download Print this page

Configuring Smon Mib Port Mirroring - Enterasys Matrix C2 C2K122-24 Release Note

Enterasys matrix c2 c2k122-24: release note
Hide thumbs Also See for Matrix C2 C2K122-24:

Advertisement

5. (Optional) Clear flood control settings.
clear cos port-resource flood-ctrl {all | group-type-index {unicast | multicast
| broadcast | all}}
clear cos port-config flood-ctrl {all | group-type-index {entry | name | ports}}
entry - Clears all settings associated with the specified group-type-index
name - Clears the name associated with the specified group-type-index
ports - Clears all ports associated with the specified group-type-index

Configuring SMON MIB Port Mirroring

Overview
SMON port mirroring support on Enterasys SecureStack B2, B3, C2 and C3 devices allows you to redirect traffic
on ports remotely using SMON MIBs. This is useful for troubleshooting or problem solving when network
management through the console port, telnet, or SSH is not feasible.
Procedures
Perform the following steps to configure and monitor port mirroring using SMON MIB objects.
To create and enable a port mirroring instance:
1. Open a MIB browser, such as Netsight MIB Tools.
2. In the MIB directory tree, navigate to the portCopyEntry folder and expand it.
3. Select the portCopyStatus MIB.
4. Enter a desired source and target port in the Instance field using the format source.target.
Example: 3.2 would create a relationship where source port ge.1.3 would be mirrored to target port
ge.1.2.
NOTE: In order to configure a port mirroring relationship, both source and destination interfaces must be
enabled and operational (up).
5. Enter MIB option 4 (createAndGo) and perform an SNMP Set operation.
6. (Optional) Use the CLI to verify the port mirroring instance has been created and enabled as shown in the
following example:
C3(su)->show port mirroring
Port Mirroring
==============
Source Port
Target Port
Frames Mirrored = Rx and Tx
Port Mirroring status enabled
To create a port mirroring instance without automatically enabling it:
Complete steps 1-4 above.
1.
2. Enter MIB option 5 (createAndWait) and perform an SNMP Set operation.
3. (Optional) Use the CLI to verify the port mirroring instance has been created set to disabled mode as
shown in the following example:
08/13/2008 P/N: 9038155-52
F0615-O
= ge.1.3
= ge.1.2
Subject to Change Without Notice
CUSTOMER RELEASE NOTES
Page: 40 of 41

Advertisement