Changes and Enhancements in 3.00.71
A problem which resulted in user-configured passwords being lost when upgrading from 02.01.37 to 03.00.50
has been resolved.
The dot1x command for auth-config settings is now correctly displayed in the ―show config‖ output. This will allow
these settings to be properly programmed into the device when loading a saved configuration.
Changes and Enhancements in 3.00.50
New Capabilities:
Support for layer 3 functionality including: RIPv1/v2, ACLs, IRDP, IGMPv2/v3, and traceroute. OSPF, DVMRP,
and VRRP are supported, but require the purchase of a license key to access these functionalities.
A problem causing NetSight Inventory Manager to return an invalid URL message when executing a C2
configuration upload has been resolved.
The C2 running configuration has been modified to correctly display any OSPF areaid an interface may be
configured for, including area 0.0.0.0.
An issue has been resolved whereby if a user had MAC authentication enabled and moved the stack
management to another device via the ―set switch movemanagement‖ command; an error message would be
displayed.
Policy PVID 4095 currently takes precedence over drop rules.
Policy precedence ignores the first rule during a multiple rule hit.
A problem causing port mirroring to not work, or to only display traffic from the host has been resolved.
The C2 will no longer send IGMP Membership Queries with a source IP of 0.0.0.0.
A problem with WebView causing slowness in host function has been resolved.
An issue has been resolved where if a user had MAC authentication and dynamic policy assignment enabled,
this would cause the message ―failed to notify management of learned addresses‖ to scroll across the screen.
The ―set policy rule 1 port‖ command is not supported and has been removed in this release.
An issue has been resolved in this release where when executing the command ―show vlan static‖ the output will
correctly list the gigabit ports as ge.unit.port.
When assigning switch characteristics to a port, a user can now freely use port ranges instead of having to
assign the characteristics to each port individually (i.e., ―set gvrp disable ge.1.49-50‖).
An issue existed whereas when upgrading the C2 from 1.1.11 to 2.00.48 port(s) become unusable until
additional resets are made. This issue has been resolved when upgrading from 2.xx.xx to 3.00.50, but may still
occur when upgrading from 01.xx.xx. It is recommended when upgrading from 1.xx.xx to 3.00.50 that a user first
upgrade to 2.01.37 to avoid experiencing this issue.
Changes and Enhancements in 2.01.37
A function has been added to support dual images, allowing the user to choose which image to boot. After
downloading the second image to the device, the user can select to boot from the backup image using the ―set
boot system‖ command. The user can also use the ―show boot system‖ command to display the current system
image. The ―dir‖ command will list the both the active and backup image on the unit. To remove a backup
image, the user must execute the command ―delete <image name>‖. Only the backup image may be deleted.
A function has been added for configuring daylight savings time on the device. The CLI command set for this
function includes ―set summertime enable | disable,‖ ―set summertime recurring‖ (for setting starting and ending
times at a specific day of the month and hour each year, without having to reset annually), ―set summertime
date,‖ (for non-recurring settings that must be reset annually), ―clear summertime‖, and ―show summertime.‖
The commands must be configured in the order shown:
1. set summertime recurring | date (specific starting and ending dates)
2. set summertime enable
3. set time