Viessmann Vitodens 333 Service Instructions Manual page 77

Compact gas fired condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 333:
Table of Contents

Advertisement

Checking and acknowledging faults
Display
Const.
fault code
9C
X
9F
X
A7
b0
X
b8
X
b1
X
b4
X
b5
X
b7
X
bA
Weat-
System
h.
character-
comp.
istics
X
X
Control
mode
X
Control
mode
X
Burner
blocked
X
X
Control
mode
X
Emissions
test mode
X
Control
mode
X
Burner
blocked
X
Mixer M2
continues
to regulate
Troubleshooting
(cont.)
Cause
Remedy
Cylinder tempera-
ture sensor lead
break
Solar control unit
See solar
fault message
control unit
service in-
structions
Faulty program-
Replace pro-
ming unit
gramming
unit
Flue gas tempera-
Check flue
ture sensor shorted
gas tempera-
out
ture sensor
(see page 87)
Flue gas temp.
sensor lead break
Communication
Check con-
fault – program-
nections and
ming unit (internal)
replace pro-
gramming
unit, if neces-
sary
Internal fault ana-
Replace con-
log converter
trol unit
Internal fault
Replace con-
trol unit
Boiler coding card
Plug in boiler
missing, faulty or
coding card
incorrect card in-
or replace, if
serted
faulty
Communication
Check exten-
fault – extension kit
sion kit con-
for mixer circuit M2
nections and
coding. Start
extension kit.
77