Viessmann Vitodens 333 Service Instructions Manual page 76

Compact gas fired condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 333:
Table of Contents

Advertisement

Troubleshooting
Checking and acknowledging faults
Display
Const.
fault code
30
X
38
X
40
48
50
X
58
X
51
X
59
X
92
X
9A
X
93
X
9B
X
94
X
76
Weat-
System
h.
character-
comp.
istics
X
Burner
blocked
X
X
Mixer
closes
X
X
No DHW
heating
X
X
No DHW
heating
X
X
Control
mode
X
X
Control
mode
X
X
Control
mode
(cont.)
Cause
Remedy
Boiler temperature
Check boiler
sensor shorted out
temperature
sensor (see
page 84)
Boiler temperature
sensor lead break
Heating circuit M2
Check flow
flow temperature
temperature
sensor shorted out
sensor
Heating circuit M2
flow temperature
sensor lead break
Cylinder tempera-
Check sen-
ture sensor/comfort
sors (see
sensor/loading
page 84)
sensor shorted out
Cylinder tempera-
ture sensor/comfort
sensor/loading
sensor lead break
Cylinder tempera-
Check sen-
ture sensor 2/outlet
sors (see
sensor shorted out
page 84)
Cylinder tempera-
ture sensor 2/outlet
sensor lead break
Solar: Collector
Check sensor
temperature sensor
shorted out
Collector tempera-
ture sensor lead
break
Solar: Sensor S3
Check sensor
shorted out
Sensor S3 lead
break
Solar: Cylinder
Check sensor
temperature sensor
shorted out

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws3a

Table of Contents