Coding
Code 2
(cont.)
Coding in
Function mode
the as de-
livered
condition
Address:
value
will be raised to the
value selected as set
room temperature, if the
system is in standard
room temperature
mode.
FA:20
Raising the set flow
temperature for the
transition from reduced
temperature mode to
standard room tempera-
ture mode = 20 %
Fb:30
Duration for raising the
set flow temperature
(see coding address
FA): 60 min
Mixer circuit
F2:8
*
1
Time limit for party
operation 8 hours or ex-
ternal operating mode
changeover via push
*
2
button
F5:12
*
3
*
3
Run-on time of the
internal circulation
pump in heating mode
F6:0
*
3
*
3
In "DHW only" oper-
ating mode, the internal
circulation pump is per-
manently OFF
*1
Only for weather-compensated control units.
In heating program rw, the party mode ends automatically when changing over to
*2
operation with standard room temperature.
*3
Only for constant temperature control units.
60
Coding
Possible change
change
Address:
value
dard mode adjustable
from +10 to -60 °C
FA:0
Raising the set flow tem-
to
perature for the transition
FA:50
from reduced tempera-
ture mode to standard
room temperature mode
adjustable from 0 to 50%
Fb:0
Duration for raising the
to
set flow temperature ad-
Fb:150
justable from 0 to 150
(corresponds to 0 to 300
min)
F2:0
No time limit for party
mode
F2:1
Time limit adjustable from
to
1 to 12 hours
F2:12
F5:0
No run-on time of the in-
ternal circulation pump
F5:1
Run-on time of the inter-
to
nal circulation pump ad-
F5:20
justable from 1 to 20 min
F6:1
Internal circulation pump
to
in "DHW only" operating
F6:24
mode will be started 1 to
24 times per day for
10 min respectively.
*