Coding
Code 2
(cont.)
Coding in
Function mode
the as de-
livered
condition
Address:
value
63:0
*
1
Without auxiliary func-
tion for DHW loading
65:...
Information regarding
the type of diverter
valve (not adjustable)
6C:100
Set speed internal DHW
loading pump 100 %
6F:100
Max. output during
DHW loading 100 %,
defaulted by the boiler
coding card
71:0
*
2
DHW circulation
pump: On according to
DHW time program ON
(Vitotrol 300 enables
separate switching
times)
72:0
*
2
DHW circulation
pump: On according to
DHW time program ON
73:0
*
2
DHW circulation
pump: On according to
DHW time program ON
General
76:0
*
2
Without LON commu-
nication module
*1
Only for constant temperature control units.
*2
Only for weather-compensated control units.
48
Coding
Possible change
change
Address:
value
63:1
Additional function: 1 x
daily
63:2
every 2 to every 14 days
to
63:14
63:15
2 x daily
65:0
Without diverter valve
65:1
Viessmann diverter valve
65:2
Wilo diverter valve
65:3
Grundfos diverter valve
6C:0
Set speed adjustable
to
from 0 to 100 %
6C:100
6F:0
Max. output during DHW
to
loading adjustable from 0
6F:100
to 100 %
71:1
OFF during DHW loading
to set value 1
71:2
ON during DHW loading
to set value 1
72:1
OFF during DHW loading
to set value 2
72:2
ON during DHW loading
to set value 2
73:1
during the time program
to
1x/h ON for 5 min
73:6
up to 6x/h ON for 5 min
73:7
constantly ON
76:1
With LON communication
module; automatic recog-
nition