Specifications
6.2 EMC Emission Test Results
6.2.1 EMC Emission Test Results
The following test results have been obtained using a system with a frequency converter, a shielded control cable, a control
box with potentiometer, and a shielded motor cable.
RFI Filter
Conduct emission. Maximum shielded cable length [m(ft)]
Type
Industrial environment
EN 55011
Class A Group 2
Category C3
EN/IEC
Second environment
61800-3
Industrial
Without
With
external
external
filter
filter
H4 RFI filter (EN55011 A1, EN/IEC61800-3 C2)
0.25–11 kW
(0.33–15
HP)
–
–
3x200–240
V IP20
0.37–22 kW
(0.5-30 HP)
–
–
3x380–480
V IP20
H2 RFI filter H2 RFI filter (EN 55011 A2, EN/IEC 61800-3 C3)
15–45 kW
(20-60 HP)
25 (82)
–
3x200–240
V IP20
30–90 kW
3x380–480
25 (82)
–
V IP20
H3 RFI filter (EN55011 A1, EN/IEC 61800-3 C1)
15–45 kW
(20-60 HP)
–
–
3x200–240
V IP20
30–90 kW
(40-125 HP)
–
–
3x380–480
V IP20
Table 6.6 EMC Test Results
BAS-SVX58D-EN
TR150 and TR170 Quick Guide
Housing, trades and
light industries
Class A Group 1
Class B
Category C2
Category C1
First environment
First environment
Home and office
Home and office
Without
With
Without
external
external
external
filter
filter
filter
25 (82)
50 (164)
–
25 (82)
50 (164)
–
–
–
–
–
–
–
50 (164)
–
20 (66)
50 (164)
–
20 (66)
08/2020 All rights reserved.
Radiated emission
Industrial environment
Class A Group 1
Category C2
First environment
Home and office
With
Without
With
external
external
external
filter
filter
filter
20 (66)
Yes
Yes
20 (66)
Yes
Yes
–
No
–
–
No
–
–
Yes
–
–
Yes
–
Housing, trades and
light industries
Class B
Category C1
First environment
Home and office
6
Without
With
external
external
filter
filter
–
No
–
No
No
–
No
–
No
–
No
–
43