Emc Emission Test Results - Trane TR150 Quick Manual

Hide thumbs Also See for TR150:
Table of Contents

Advertisement

Specifications

6.2 EMC Emission Test Results

6.2.1 EMC Emission Test Results
The following test results have been obtained using a system with a frequency converter, a shielded control cable, a control
box with potentiometer, and a shielded motor cable.
RFI Filter
Conduct emission. Maximum shielded cable length [m(ft)]
Type
Industrial environment
EN 55011
Class A Group 2
Category C3
EN/IEC
Second environment
61800-3
Industrial
Without
With
external
external
filter
filter
H4 RFI filter (EN55011 A1, EN/IEC61800-3 C2)
0.25–11 kW
(0.33–15
HP)
3x200–240
V IP20
0.37–22 kW
(0.5-30 HP)
3x380–480
V IP20
H2 RFI filter H2 RFI filter (EN 55011 A2, EN/IEC 61800-3 C3)
15–45 kW
(20-60 HP)
25 (82)
3x200–240
V IP20
30–90 kW
3x380–480
25 (82)
V IP20
H3 RFI filter (EN55011 A1, EN/IEC 61800-3 C1)
15–45 kW
(20-60 HP)
3x200–240
V IP20
30–90 kW
(40-125 HP)
3x380–480
V IP20
Table 6.6 EMC Test Results
BAS-SVX58D-EN
TR150 and TR170 Quick Guide
Housing, trades and
light industries
Class A Group 1
Class B
Category C2
Category C1
First environment
First environment
Home and office
Home and office
Without
With
Without
external
external
external
filter
filter
filter
25 (82)
50 (164)
25 (82)
50 (164)
50 (164)
20 (66)
50 (164)
20 (66)
08/2020 All rights reserved.
Radiated emission
Industrial environment
Class A Group 1
Category C2
First environment
Home and office
With
Without
With
external
external
external
filter
filter
filter
20 (66)
Yes
Yes
20 (66)
Yes
Yes
No
No
Yes
Yes
Housing, trades and
light industries
Class B
Category C1
First environment
Home and office
6
Without
With
external
external
filter
filter
No
No
No
No
No
No
43
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tr170