Specifications
6.1.3 3x525–600 V AC
Frequency converter
Typical shaft output
[kW]
Typical shaft output
[hp]
Protection rating IP20
Maximum cable size
in terminals (mains,
motor)
[mm
2
(AWG)]
Output current - 40 °C (104 ° F) ambient temperature
Continuous (3x525–
550 V) [A]
6
6
Intermittent (3x525–
550 V) [A]
Continuous (3x551–
600 V) [A]
Intermittent (3x551–
600 V) [A]
Maximum input current
Continuous (3x525–
550 V) [A]
Intermittent (3x525–
550 V) [A]
Continuous (3x551–
600 V) [A]
Intermittent (3x551–
600 V) [A]
Maximum mains fuses
Estimated power loss
[W], best case/
typical
1)
Weight enclosure
protection rating IP54
[kg (lb)]
Efficiency [%],
best case/typical
Output current - 50 °C (122 °F) ambient temperature
Continuous (3x525–
550 V) [A]
Intermittent (3x525–
550 V) [A]
Continuous (3x551–
600 V) [A]
Intermittent (3x551–
600 V) [A]
Table 6.5 3x525–600 V AC, 2.2–90 kW (3–125 hp), Enclosure Sizes H6–H10
1) Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
increase. Keypad and typical control card power consumptions are included.
2) Efficiency measured at nominal current. For energy efficiency class, see chapter 6.4.10 Ambient Conditions.
42
P2K2 P3K0 P3K7 P5K5 P7K5 P11K P15K P18K P22K P30K P37K P45K P55K P75K P90
2.2
3.0
3.7
5.5
3.0
4.0
5.0
7.5
H9
H9
H9
H9
4 (10) 4 (10) 4 (10) 4 (10) 4 (10) 10 (8) 10 (8) 35 (2) 35 (2)
4.1
5.2
6.4
9.5
4.5
5.7
7.0
10.5
3.9
4.9
6.1
9.0
4.3
5.4
6.7
9.9
3.7
5.1
5.0
8.7
4.1
5.6
6.5
9.6
3.5
4.8
5.6
8.3
3.9
5.3
6.2
9.2
65
90
110
132
6.6
6.6
6.6
6.6
(14.6)
(14.6)
(14.6)
(14.6)
97.9
97
97.9
98.1
2)
2.9
3.6
4.5
6.7
3.2
4.0
4.9
7.4
2.7
3.4
4.3
6.3
3.0
3.7
4.7
6.9
TR150
7.5
11.0
15.0
18.5
10.0
15.0
20.0
25.0
H9
H10
H10
H6
11.5
19.0
23.0
28.0
12.7
20.9
25.3
30.8
11.0
18.0
22.0
27.0
12.1
19.8
24.2
29.7
11.9
16.5
22.5
27.0
13.1
18.2
24.8
29.7
11.4
15.7
21.4
25.7
12.5
17.3
23.6
28.3
See chapter 3.2.3 Fuses and Circuit Breakers.
180
216
294
385
6.6
11.5
11.5
24.5
(14.6)
(25.3)
(25.3)
(54)
98.1
98.4
98.4
98.4
8.1
13.3
16.1
19.6
8.9
14.6
17.7
21.6
7.7
12.6
15.4
18.9
8.5
13.9
16.9
20.8
08/2020 All rights reserved.
22.0
30.0
37
45.0
55.0
30.0
40.0
50.0
60.0
70.0
H6
H6
H7
H7
H7
35
50
50
50
(2)
(1)
(1)
(1)
36.0
43.0
54.0
65.0
87.0
39.6
47.3
59.4
71.5
95.7
34.0
41.0
52.0
62.0
83.0
37.4
45.1
57.2
68.2
91.3
33.1
45.1
54.7
66.5
81.3
36.4
49.6
60.1
73.1
89.4
31.5
42.9
52.0
63.3
77.4
34.6
47.2
57.2
69.6
85.1
458
542
597
727
1092 1380 1658
24.5
24.5
36.0
36.0
36.0
(54)
(54)
(79.3)
(79.3)
(79.3)
98.4
98.5
98.5
98.7
98.5
25.2
30.1
37.8
45.5
60.9
27.7
33.1
41.6
50.0
67.0
23.8
28.7
36.4
43.3
58.1
26.2
31.6
40.0
47.7
63.9
TR170
P1K5
K
75.0
90.0
1.5
100.0 125.
2.0
0
H8
H8
H9
120
95 (0)
4 (10)
(4/0)
105.0 137.
2.9
0
115.5 150.
3.2
7
100.0 131.
2.7
0
110.0 144.
3.0
1
109.0 130.
2.6
9
119.9 143.
2.9
9
103.8 124.
2.4
5
114.2 137.
2.6
0
63
51.0
51.0
6.6
(112.
(112.
(14.6)
4)
4)
98.5
98.5
96.0
70 °C
(158 °
F)
73.5
95.9
2.9
80.9
105.
3.2
5
70.0
91.7
2.7
77.0
100.
3.0
9
BAS-SVX58D-EN