Horizontal Installation - ClimateMaster Tranquility 30 Digital TE Series Installation, Operation & Maintenance Instructions Manual

Residential horizontal, vertical & downflow packaged geothermal heat pumps
Hide thumbs Also See for Tranquility 30 Digital TE Series:
Table of Contents

Advertisement

Tranquility
30 Digital ( TE) Series IOM - 60Hz HFC-410A
®
R e v . : O c t o b e r 5 , 2 0 2 1

Horizontal Installation

Figure 5: Horizontal Unit Pitch
Return Air
1/4" (6.4mm) pitch
toward drain
Drain
Connection
Figure 3: Typical Horizontal Unit Installation with Internal Flow Controller
CCP=Control/Compressor Access Panel
BSP=Blower Service Panel
ASP=Additional Service Panel (not required)
Notes:
1. While clear access to all removable panels is not required, installer should
take care to comply with all building codes and allow adequate clearance
for future field service.
2. Blower service panel requires 2' service access.
3. Blower service access is through back panel on straight discharge units or
through panel opposite air coil on back discharge units.
TE HORIZONTAL INSTALLATION
Supply Air
Figure 3: Typical Horizontal Unit Installation with Internal Motorized Modulating Valve
Insulated supply duct with
Use turning vanes
at least one 90 deg elbow
or a double
radius elbow
to reduce air noise
Supply Air
Insulated supply duct with
at least one 90 deg turn
to reduce air noise
Flexible Duct
Connector
Supply Air
Figure 6: Horizontal Unit Mounting
Air Coil - To obtain maximum performance, the air coil should be
cleaned before start-up. A 10% solution of dishwasher detergent
Insulated supply duct with
and water is recommended for both sides of the coil. A thorough
at least one 90 deg elbow
water rinse should follow.
to reduce air noise
8
CCP
Front
ASP
2' [61cm] optional
service access
Straight
HORIZONTAL INSTALLATION
Discharge
BSP for Back Discharge
Back
Discharge
BSP for Straight Discharge
Legend
3/8" [10mm] threaded rods
(by others)
HORIZONTAL INSTALLATION
Flexible Duct
Return
Connector
Duct
Power Wiring
Flexible Duct
Connector
Unit Power
Unit Power
Disconnect
(by others)
Platform
Unit
Secondary
Hanger
Drain Pan
Flexible Duct
Connector
G e o t h e r m a l H e a t i n g a n d C o o l i n g
2' [61cm] Service
Access
ASP
3/8" [10mm] threaded rods
(by others)
Return Air
Power Wiring
Unit Power
3/8" [10mm] threaded rods
(by others)
Unit Power
Disconnect
Unit Hanger
(by others)
Vibration
Isolation Pad
Return Air
Power Wiring
Thermostat
Wiring
Unit Power
Unit Power
Disconnect
Unit Hanger
(by others)
Figure 6a: Typical Closed Loop Horizontal
Unit Installation (with Internal Flow
Controller)
Water
Pressure Ports
Water Out
Water In
Flush
Ports
Internal
Variable-Speed
Pump
Figure 6b: Typical Ground Water Horizontal
Unit Installation (with Internal Motorized
Modulating Valve)
Water
Pressure Ports
Ball Valves
Boiler
Drains
Internal Motorized
Modulating Valve
Water
Pressure
Out
Tank
Water In