Tranquility ® High Efficiency (TR) Series Table of Contents Model Nomenclature - General Overview General Information Unit Physical Data Hydronic Heating Physical Data Horizontal Installation Field Conversion of Air Discharge Horizontal Installation Vertical Installation 12-13 Piping Installation Water-Loop Heat Pump Applications Ground-Loop Heat Pump Applications 16-17 Ground-Water Heat Pump Applications...
UV based anti-bacterial systems may damage (e.g. louvered door). Therefore, filter rails are the industry e-coated air coils. standard and are included on ClimateMaster commercial heat pumps for the purposes of holding the filter only. For ducted return applications, the filter rail must be removed and replaced with a duct flange or filter frame.
(e.g. louvered door). Therefore, filter rails are the industry duct for first 1.2 m each way to reduce noise standard and are included on ClimateMaster commercial Use turning vanes in heat pumps for the purposes of holding the filter only. For...
Page 13
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tr a n q u i l i t y ( T R ) S e r i e s ®...
Optional pressure-rated hose assemblies designed unnecessary noise complaints. specifically for use with ClimateMaster units are available. Similar hoses can be obtained from alternate suppliers. Supply and return hoses are fitted with swivel-joint Figure 11: Supply/Return Hose Kit fittings at one end to prevent kinking during installation.
[2.9 and 4.5 l/m per kW] of cooling capacity. mechanical room plumbing. Consideration should be given ClimateMaster recommends 3 gpm per ton [3.9 l/m per kW] to insulating the piping surfaces to avoid condensation. for most applications of water loop heat pumps. To ensure...
20 mesh] size. The ClimateMaster Water Quality Table provides water quality requirements for ClimateMaster coaxial heat exchangers. The water should be evaluated by an independent testing facility comparing to this Table and when properties are outside of these requirements, an external secondary heat exchanger must be used to isolate the heat pump heat exchanger from the unsuitable water.
Figure Electrical Code as well as all applicable local codes. Refer 16. Most ClimateMaster units are shipped on the medium to the unit electrical data for fuse sizes. Consult wiring speed tap. Consult submittal data or engineering design diagram for field connections that must be made by guide for specific unit airflow tables.
Figure 17 to change the setting to 10°F [-12.2°C] refrigerant temperature, a more suitable temperature when using an antifreeze solution. All ClimateMaster units operating with entering water temperatures below 60°F [15.6°C] must include the optional water/refrigerant circuit insulation package to prevent internal condensation.
Figures 19 and 20 illustrate typical slow closing water control valve wiring for Taco 500 series (ClimateMaster P/N AVM) and Taco SBV series valves. Slow closing valves take approximately 60 seconds to open (very little water will flow before 45 seconds).
IOM and or Heat Pump Thermostat DXM2 unit wiring diagram. Practically any heat pump thermostat will work with ClimateMaster heat pump units, provided Compressor it has the correct number of heating and cooling stages. Common 24v...
R e v . : N o v e m b e r 2 , 2 0 2 0 TR Series Wiring Diagram Matrix All current diagrams can be located online at climatemaster.com. Click ‘Commercial Professional’ (go to ‘Resources/literature/wiring diagrams’ in the upper right), use part numbers below to lookup wiring diagrams...
The DXM2 control board will bring the unit on in 2nd Stage cooling/heating modes are like any other ClimateMaster Heating. When the call is satisfied at the thermostat WSHP. The reversing valve (“O” signal) is energized...
Page 72
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Tr a n q u i l i t y ( T R ) S e r i e s ®...
Page 73
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tr a n q u i l i t y ( T R ) S e r i e s ®...
ClimaDry to operate properly. 4. Verify that all strainers are in place (ClimateMaster recommends a strainer with a #20 stainless steel wire Note: The manufacturer strongly recommends all piping mesh).
5. Two factors determine the operating limits of d. Refer to table 9. Check the temperature of both ClimateMaster heat pumps, (a) return air temperature, entering and leaving water. If temperature is within and (b) water temperature. When any one of these range, proceed with the test.
Page 79
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tr a n q u i l i t y ( T R ) S e r i e s ®...
Location: ________________________ Model Number: ________________________ T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Serial Number: ________________________ Date: ________________________ Packaged Unit Refrigeration Schematic...
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications.