Troubleshooting Form - ClimateMaster Tranquility 30 Digital TE Series Installation, Operation & Maintenance Instructions Manual

Residential horizontal, vertical & downflow packaged geothermal heat pumps
Hide thumbs Also See for Tranquility 30 Digital TE Series:
Table of Contents

Advertisement

Customer:
Model #:
Complaint:
10
11
AIR
CONDENSER (HEATING)
COIL
EVAPORATOR (COOLING)
9
LT2:
HEATING
LIQUID
LINE
Description
1 Water In Temp.
2 Water Out Temp.
3 Water In Pressure
4 Water Out Pressure
4a Pressure Drop
4b GPM
Heat of Extraction (Absorption) or Heat of Rejection:
HE or HR (Btuh) =
5 Suction Temp.
6 Suction Pressure
6a Saturation Temp.
6b Superheat
7 Discharge Temp.
8 Discharge Pressure
8a Saturation Temp.
8b Subcooling
9 Liquid Line Temp
10 Return Air Temp.
11 Supply Air Temp.
Voltage
Compress Amps
Note: Never connect refrigerant gauges during startup procedures. Conduct water-side analysis using P/T ports to determine
water flow and temperature difference. If water-side analysis shows poor performance, refrigerant troubleshooting may be
required. Connect refrigerant gauges as a last resort.
Tranquility
Packaged Water-to-Air

Troubleshooting Form

Loop Type:
Serial #:
REFRIGERANT:
R-22
OPERATING MODE:
HEATING
REFRIG FLOW - HEATING
CONDENSER (COOLING)
EVAPORATOR (HEATING)
EXPANSION
FILTER
VALVE
DRIER*
9
LT1:
COOLING
1
LIQUID
LINE
3
Heating
Water Side Analysis
Enter HE or HR:
Flow Rate (GPM) x
Refrigerant Analysis
c l i m a t e m a s t e r . c o m
30 Digital ( TE) Series IOM - 60Hz HFC-410A
®
Antifreeze Type & %:
R-410A
COOLING
REFRIG FLOW - COOLING
REVERSING
VALVE
COAX
HWG**
Source
2
4
Cooling
Temp. Diff . =
Temp. Diff (deg F) x
Temp. Diff . =
R e v . : O c t o b e r 5 , 2 0 2 1
Troubleshooting Form
Startup Date:
HEATING POSITION
COOLING POSITION
6
5
SUCTION
COMPRESSOR
7
DISCHARGE
8
* Filter drier not used
for some R-22 units.
** Turn off HWG before
troubleshooting.
Notes
Fluid Factor:
500 (Water); 485 (Antifreeze)
Fluid Factor
RP929
65