Electrical-Line Voltage - ClimateMaster Tranquility 30 Digital TE Series Installation, Operation & Maintenance Instructions Manual

Residential horizontal, vertical & downflow packaged geothermal heat pumps
Hide thumbs Also See for Tranquility 30 Digital TE Series:
Table of Contents

Advertisement

Tranquility
30 Digital ( TE) Series IOM - 60Hz HFC-410A
®
R e v . : O c t o b e r 5 , 2 0 2 1
Electrical - Line Voltage
WARNING! To avoid possible injury or death due to
electrical shock, open the power supply disconnect switch
and secure it in an open position during installation.
CAUTION! Use only copper conductors for field installed
electrical wiring. Unit terminals are not designed to accept
other types of conductors.
Table 7a: Tranquility 30
Compressor
Model
RLA
LRA
026
11.7
58.3
038
15.3
83.0
049
21.2
104.0
064
27.1
152.9
072
29.7
179.2
Rated Voltage of 208/230/60/1
Table 7b: Tranquility 30
with High Head Internal Flow Controller
Compressor
Model
RLA
LRA
026
11.7
58.3
038
15.3
83.0
049
21.2
104.0
064
27.1
152.9
072
29.7
179.2
Rated Voltage of 208/230/60/1
Table 7c: Tranquility 30
with Standard Head Internal Flow Controller
Compressor
Model
RLA
LRA
026
11.7
58.3
038
15.3
83.0
Rated Voltage of 208/230/60/1
WARNING! Disconnect electrical power source to prevent
injury or death from electrical shock.
CAUTION! Use only copper conductors for field installed
electrical wiring. Unit terminals are not designed to accept
other types of conductors.
32
WARNING!
CAUTION!
(TE) Series Electrical Data
®
External
HWG
Fan
Total
Loop
Pump
Motor
Unit
Pump
FLA
FLA
FLA
Qty
FLA
1
0.5
4.0
3.9
20.1
1
0.5
4.0
3.9
23.7
1
0.5
4.0
6.9
32.6
1
0.5
4.0
6.9
38.5
1
0.5
4.0
6.9
41.1
Min/Max Voltage of 197/254
All fuses Class RK-5
(TE) Series Electrical Data
®
HWG
Loop
Fan
Total
Pump
Pump
Motor
Unit
FLA
FLA
FLA
FLA
Qty
1
0.5
1.44
3.9
17.5
1
0.5
1.44
3.9
21.1
1
0.5
1.44
6.9
30.0
1
0.5
1.44
6.9
35.9
1
0.5
1.44
6.9
38.5
Min/Max Voltage of 197/254
All fuses Class RK-5
(TE) Series Electrical Data
®
HWG
Loop
Fan
Total
Pump
Pump
Motor
Unit
FLA
FLA
FLA
FLA
Qty
1
0.5
0.7
3.9
16.8
1
0.5
0.7
3.9
20.4
Min/Max Voltage of 197/254
All fuses Class RK-5
WARNING!
CAUTION!
G e o t h e r m a l H e a t i n g a n d C o o l i n g
Electrical - Line Voltage
All field installed wiring, including electrical ground, must
comply with the National Electrical Code as well as all
applicable local codes. Refer to the unit electrical data for fuse
sizes. Consult wiring diagram for field connections that must
be made by the installing (or electrical) contractor.
All final electrical connections must be made with a length of
flexible conduit to minimize vibration and sound transmission
to the building.
General Line Voltage Wiring
Be sure the available power is the same voltage and phase
shown on the unit serial plate. Line and low voltage wiring
Min
Max/
must be done in accordance with local codes or the National
Circuit
Fuse
Electric Code, whichever is applicable.
Amps
HACR
Power Connection
23.0
30
Line voltage connection is made by connecting the incoming
27.5
40
line voltage wires to the "L" side of the contactor as shown in
37.9
50
Figure 25. Consult Tables 7a through 7c for correct fuse size.
Note: always refer to the unit dataplate for unit electrical data.
45.2
70
48.5
70
208 Volt Operation
All residential 208/230 Volt units are factory wired for 230
Volt operation. The transformer may be switched to the 208V
tap as illustrated on the wiring diagram by switching the red
(208V) and the orange (230V) wires at the contactor terminal.
Min
Max/
Circuit
Fuse
Figure 25: Tranquility Single Phase Line Voltage
Amps
HACR
Field Wiring
20.4
30
24.9
40
35.3
50
42.7
70
45.9
70
Min
Max/
Circuit
Fuse
Amps
HACR
19.7
30
24.2
35
(see electrical tables 7a - 7c for minimum
circuit amps and maximum breaker size)
Unit Power Supply