Tranquility Vertical Stack ® (TSM/TSL) Series Table of Contents General Information – Inspection C, D, & E Cabinet Series Model Nomenclature TSM/TSL Chassis Series Model Nomenclature Accessory Nomenclature 8-10 Physical Data 11-13 Pre-Installation Information Riser & Cabinet Installation 15-21 Leader/Follower Cabinet Installation C &...
Page 2
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Table of Contents, Cont’d.
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 C Cabinet Series Model Nomenclature –...
Page 5
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 6
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 E Cabinet Series Model Nomenclature –...
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Accessory Nomenclature Return Air Panel “G”...
Page 9
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 10
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Accessory Nomenclature, Cont’d.
170 [77] 88” Cabinet - (lbs) [kg] 128 [58] 148 [67] 185 [84] Unit wiring diagrams available at www.climatemaster.com. Select 'Commercial Professional ', ' Literature ', ' Wiring Diagrams'. Unit Maximum Water Working Pressure Max Pressure PSIG Options [kPa] Base Unit (Hoses)
Page 12
192 [87] 65” Cabinet - (lbs) [kg] 95 [43] 108 [49] 142 [64] Unit wiring diagrams available at www.climatemaster.com. Select 'Commercial Professional ', ' Literature ', ' Wiring Diagrams'. Unit Maximum Water Working Pressure Max Pressure PSIG Options [kPa] Base Unit (Hoses)
Page 13
156 [71] 88” Cabinet - (lbs) [kg] 137 [63] 151 [69] 166 [76] Unit wiring diagrams available at www.climatemaster.com. Select 'Commercial Professional ', ' Literature ', ' Wiring Diagrams'. Unit Maximum Water Working Pressure Max Pressure PSIG Options [kPa] Base Unit...
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Pre-Installation Information Storage - Equipment should be stored in its original 5.
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 16
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Riser and Cabinet Installation, Cont’d.
Page 17
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 18
When installation is complete, cover all cabinet openings and exposed sheet metal. (Cardboard from unit shipping NOTICE! ClimateMaster is not responsible for wallboard cartons can be used). Do not allow paint or wall texture repair if 2 x 4 box was not in correct orientation.
Page 19
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 20
Standard riser diameters are nominal 1”, 1¼”, 1½”, 2”, 2½”, and 3”. Please consult the factory on pricing for nominal 4” water tubing. Copper Type M and L available (4" L only). Note: ClimateMaster units Drain riser insulated standard. Insulation is optional for supply and return with motorized valve option Leader riser - For follower cabinet riser ball valve assemblies, 12”...
Page 21
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Leader/Follower Cabinet Installation Field connect hoses in both cabinets-...
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 E Cabinet Slot Dimensions and Riser Arrangements 0.25”...
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Supply Grille Installation Supply Grille Installation - Cabinet opening should be sealed to wall.
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Typical Cabinet with “G”...
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Drywall Openings NOTICE - Drywall openings shown below are for specific cabinets as indicated.
Page 31
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Flushing Procedures” in this manual). The flow rate is usually set between 2.25 and 3.5 gpm per ton [2.9 and 4.5 l/m per kW] of cooling capacity. ClimateMaster recommends 3 gpm per ton [3.9 l/m per kW] for most applications of water loop heat pumps.
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Ground-Loop Heat Pump Applications ⚠...
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 36
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Ground-Water Heat Pump Applications, Cont’d.
20 mesh] size. The ClimateMaster Water Quality Table provides water quality requirements for ClimateMaster coaxial heat exchangers and fluid coolers. The water should be evaluated by an independent testing facility comparing to this Table and when properties are outside of these requirements, an external secondary heat exchanger must be used to isolate the equipment from the unsuitable water.
DXM2/ M para velocidad de ventilador media 1 Stage Med TAP L para velocidad de ventilador baja Azul Unit wiring diagrams available at www.climatemaster. DXM2 2 Stage com. Select ‘Commercial Professional‘, ‘Literature‘, ‘Wiring Med TAP Auto Speed La configuración de fábrica es velocidad High TAP Diagrams’...
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Blower Performance Data –...
Page 41
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 42
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Blower Performance Data –...
Page 43
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 44
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Blower Performance Data –...
Page 45
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 46
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Blower Performance Data –...
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 48
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Blower Performance Data –...
Page 49
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 50
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Blower Performance Data –...
Page 51
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 52
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Blower Performance Data –...
JW3 must be clipped as shown in Figure 13. Lowest refrigerant temperature, LT1 can sense without faulting off is, with LT1 unclipped - 30ºF (-1ºC) and clipped - 10ºF (-12ºC). All ClimateMaster units operating with entering water temperatures below 59°F [15°C] must include the optional water/refrigerant circuit insulation package to prevent internal condensation.
Will provide auto speed change (for CXM connect Y2 to blower relay coil - see unit wire diagram). Figure 24a: Communicating Thermostat Unit wiring diagrams available at www.climatemaster.com. Figure 14a: Communicating Thermostat to DXM2 Connection to DXM2 Control Select ‘Commercial Professional ‘, ‘ Literature ‘,...
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Chassis Pre-Installation See Figures 15-18 b.
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 58
1" (25.4) 5.5 (139.7) water leaks. ClimateMaster WILL NOT be responsible or liable for damage caused by water leaks at any field water Do not bend hoses at less than the minimum bend radius connections! for the hose selected.
Page 59
After the system has been filled and system pump is started, all connections should be re-checked for water leaks. ClimateMaster WILL NOT be responsible or liable for damage caused by water leaks at any field water connections! 8.
4. Adjust the water and air level in the expansion tank. safety cutouts, and alarms. Set controls to properly 5. With strainers in place, (ClimateMaster recommends maintain loop temperature. a strainer with a #20 stainless steel wire mesh) start the pumps.
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Unit Commissioning and Operating Conditions Environment - This unit is designed for indoor installation The commissioning table 11 indicates air and water...
12. BE CERTAIN TO FILL OUT AND FORWARD maximum ranges of Tables 11 & 12. During start-up ALL WARRANTY REGISTRATION PAPERS TO checks, loop water temperature entering the heat CLIMATEMASTER. pump should be between 60°F [16°C] and 95°F [35°C] Note: If performance during any mode appears 5.
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 70
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Unit Operating Pressures and Temperatures, Cont’d.
Page 71
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Coax Water Pressure Drop Pressure Drop, PSI PD Added for...
Compressor Allow unit to run 15 minutes in each mode before taking data. Do not connect refrigerant gauges during start up unless instructed by ClimateMaster service tech. *Temperatures can be read with service tool or communicating thermostat. c l i m a t e m a s t e r . c o m...
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Preventive Maintenance Water Coil Maintenance the problem.
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Performance Troubleshooting Performance Troubleshooting Htg Clg Possible Cause...
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 78
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Wire Harnesses for 09-12 ECM-CT w/DXM2 Use for Wire Harness Part Numbers Only 2 X 4...
Page 79
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 80
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Wire Harness for 15-36 ECM-CV Motor Use for Wire Harness Part Numbers Only 2 X 4...
Page 81
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 82
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Wire Harnesses for 15-36 ECM-CT Motor w/CXM Use for Wire Harness Part Numbers Only 2 X 4...
Page 83
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 84
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Troubleshooting Form Water-to-Air Units Model #:...
Page 85
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 86
C L I M AT E M A S T E R WAT E R - S O U R C E H E AT P U M P S TSM/ TSL Ver tical Stack R e v . : J a n u a r y 1 8 , 2 0 2 1 Notes: C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s...
Page 87
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y TSM/ TSL Ver tical Stack R e v .
Page 88
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications.