Tranquility ® COMPACT (TC) Series Table of Contents Model Nomenclature – General Overview General Information Unit Physical Data Horizontal Installation Field Conversion of Air Discharge Horizontal Installation Vertical Installation Piping Installation Water-Loop Heat Pump Applications Ground-Loop Heat Pump Applications Ground-Water Heat Pump Applications Water Quality Standards TC - Horizontal –...
Page 2
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Tranquility Compact ( TC) Series ® R e v .
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact ( TC) Series ®...
Page 8
UV based anti-bacterial systems may damage (e.g. louvered door). Therefore, filter rails are the industry e-coated air coils. standard and are included on ClimateMaster commercial heat pumps for the purposes of holding the filter only. For ducted return applications, the filter rail must be removed and replaced with a duct flange or filter frame.
(e.g. louvered door). Therefore, filter rails are the industry Internally insulate supply standard and are included on ClimateMaster commercial duct for first 1.2 m each way to reduce noise heat pumps for the purposes of holding the filter only. For...
Page 12
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Tranquility Compact ( TC) Series ® R e v .
Fitting Rib Crimped Fitting Optional pressure-rated hose assemblies designed specifically for use with ClimateMaster units are available. Similar hoses can be obtained from alternate suppliers. Length (2 ft [0.6m] Length Standard) c l i m a t e m a s t e r . c o m...
[2.9 and 4.5 l/m per kW] of cooling capacity. Metal to plastic threaded joints should never be used due to ClimateMaster recommends 3 gpm per ton [3.9 l/m per kW] their tendency to leak over time. for most applications of water loop heat pumps. To ensure...
20 mesh] size. The ClimateMaster Water Quality Table provides water quality requirements for ClimateMaster coaxial heat exchangers. The water should be evaluated by an independent testing facility comparing to this Table and when properties are outside of these requirements, an external secondary heat exchanger must be used to isolate the heat pump heat exchanger from the unsuitable water.
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Tranquility Compact ( TC) Series ® R e v .
Page 21
2. Units are shipped with air filter rails that are not suitable for supporting return air ductwork. An air filter frame with duct mounting collar is available as an accessory, see the ClimateMaster Accessory Submittal set for futher information on this frame.
ClimateMaster Accessory Submittal set for futher 9. WSE to unit piping to be field fabricated, Run below or in front. Must leave room to remove front access panel (CCP) to information on this frame.
Page 23
9. WSE to unit piping to be field fabricated. Run below or in front. Must ClimateMaster Accessory Submittal set for futher leave room to remove front access panel (CCP) to service unit.
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact ( TC) Series ®...
Page 26
Units are shipped with air filter rails that are not suitable for supporting return air ductwork. An air filter frame with duct mounting collar is available as an accessory, see the ClimateMaster Accessory Submittal set for futher information on this frame.
(WSP), remove, slide onto dinrail, and duct mounting collar is available as an accessory, see the connect molex. ClimateMaster Accessory Submittal set for futher information 5. WSE to unit piping to be field fabricated, run below or in front. Must on this frame.
Page 28
4. Factory supplied controller (aquastat) is shipped inside unit. Open duct mounting collar is available as an accessory, see the waterside economizer panel (WSP), remove, slide onto dinrail, and ClimateMaster Accessory Submittal set for futher information connect molex. on this frame.
Figure including electrical ground, must comply with the National 16. Most ClimateMaster units are shipped on the medium Electrical Code as well as all applicable local codes. Refer to the unit electrical data for fuse sizes. Consult wiring speed tap.
Figure 17 to change the setting to 10°F [-12.2°C] refrigerant temperature, a more suitable temperature when using an antifreeze solution. All ClimateMaster units operating with entering water temperatures below 60°F [15.6°C] must include the optional water/refrigerant circuit insulation package to prevent internal condensation.
Taco specific unit wiring diagram for details. 500 series (ClimateMaster P/N AVM) and Taco SBV series valves. Slow closing valves take approximately 60 seconds to open (very little water will flow before Low Voltage VA Ratings 45 seconds).
Practically any heat pump thermostat will work the wall so that it appears level and so the thermostat with ClimateMaster units, provided it has the correct wires protrude through the middle of the back plate. Mark number of heating and cooling stages.
Compact ( TC) Series ® R e v . : J u l y 7 , 2 0 2 0 TC Series Wiring Diagram Matrix All current diagrams can be located online at climatemaster.com/commercial-wiring DESCRIPTION Voltage: G.E Voltage: H Voltage: F...
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact ( TC) Series ®...
Page 56
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Tranquility Compact ( TC) Series ® R e v .
Page 57
T H E S M A R T S O L U T I O N F O R E N E R G Y E F F I C I E N C Y Tranquility Compact ( TC) Series ®...
Page 58
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Tranquility Compact ( TC) Series ® R e v .
Page 59
Thermostat Compatibility – Most heat pump and heat/ cool thermostats can be used with the DXM2, as well as Resistance Resistance Temp (ºC) Temp (ºF) Temp (ºC) Temp (ºF) (kOhm) (kOhm) ClimateMaster communicating thermostats (ATC32). -17.8 85.34 131.0 2.99 -17.5 84.00 132.8 2.88 -16.9...
4. Verify that all strainers are in place (ClimateMaster connections is limited. Test pressure may not exceed recommends a strainer with a #20 stainless steel the maximum allowable pressure for the unit and all wire mesh).
5. Two factors determine the operating limits of entering and leaving water. If temperature is within ClimateMaster heat pumps, (a) return air temperature, range, proceed with the test. If temperature is and (b) water temperature. When any one of these...
Page 68
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Tranquility Compact ( TC) Series ® R e v .
Model Number: ________________________ Serial Number: ________________________ C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S Date: ________________________ Packaged Unit Refrigeration Schematic Tranquility...
ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications.