Codes
Code 1
(cont.)
Coding in the delivered condition
Charging scheme
Charging
Charging with AF flexible agitator
scheme:1
discharge
DHW
DHW:No
No DHW heating installed
DHW circulation
DHW circula-
No DHW circulation is connected
tion:No
to the boiler control unit
Extinguishing water tank
Extinguishing wa-
No extinguishing water tank instal-
ter tank:No
led
Flue gas filter
Flue gas filter:No
No flue gas filter installed
92
Possible change
Charging
External charging
scheme:0
Charging
Charging with screw conveyor and
scheme:2
external charging
Charging
Charging with screw conveyor and
scheme:3
AF flexible agitator discharge
Charging
Charging with AH discharge (screw
scheme:4
conveyor and agitator)
Charging
Charging with rotary lock valve and
scheme:5
AF flexible agitator discharge
Charging
Charging with rotary lock valve and
scheme:6
vacuum module
Charging
Charging with rotary lock valve, vac-
scheme:7
uum module and autom. changeover
unit
Charging
Charging with rotary lock valve, vac-
scheme:8
uum module and external charging
Charging
Charging with rotary lock valve, vac-
scheme:9
uum module and AF flexible agitator
discharge
Charging
Charging with rotary lock valve, vac-
scheme:10
uum module and AF mole
Charging
Charging with rotary lock valve, vac-
scheme:11
uum module and extraction screw
conveyor
Charging
External charging control panel
scheme:12
with hydraulics, transverse screw
conveyor and screw conveyor
Charging
External charging control panel
scheme:13
with rotary lock valve and pendulum
discharge AP including reversal of
rotational direction
DHW:On the boil-
DHW heating is connected to the
er
control unit of the boiler.
DHW:On the mix-
DHW heating is connected to the ex-
er module
tension kit.
DHW circula-
DHW circulation is connected to the
tion:Yes
control unit of the boiler.
Extinguishing wa-
Extinguishing water tank installed
ter tank:Yes
Flue gas filter:Ex-
Demand to flue gas filter and fault
ternal
message from flue gas filter via
floating contact
Flue gas filter:In-
Control of flue gas filter via CAN bus
ternal
(With internal: Group A3 on the HKK
PCB is occupied)