Specification
(cont.)
Fuel
Rated heating output
Installed weights
Boiler without water or
Feed (without shut-off gate valve/rotary lock valve)
■
Ash box
■
Thermal insulation
■
Boiler with water and
Feed (without shut-off gate valve/rotary lock valve)
■
Ash box
■
Thermal insulation
■
Capacity
Boiler water
Ash box
Protection class
IP rating to EN 60529; ensure through design/installation.
Type of operation to EN 60730-1
Operation of the boiler
Permiss. ambient temperature
During operation
■
(Use in boiler rooms, standard ambient conditions)
During storage and transport
■
Electrical data
Rated voltage
■
Rated frequency
■
Max. rated current
■
Power consumption
Ignition
Ash removal
Feed
Flue gas fan
Grate drive
Heat exchanger cleaning
Boiler at Q
■
N
Boiler at Q
■
min
Boiler on standby
■
Rated relay output breaking capacity at 230 V
Heating circuit pumps
Circulation pump for cylinder heating
Solar circuit pump, as alternative to heating circuit pump M2
DHW circulation pump
Central fault message
Mixer motor
Discharge motor, room discharge/silo, mole
∼
Specification
Wood-
chips
kW
50
kg
1077
kg
1287
l
210
l
45
kg
18
I
IP 20
Type 1 B
Non-con-
densing
°C
0 to +35
°C
20 to +65
−
∼
V
400
Hz
50
∼
A
10
W
1400
W
25
W
380
W
100
W
14
W
14
W
234
W
122
W
26
∼
A
4 (2)
∼
A
4 (2)
∼
A
4 (2)
∼
A
4 (2)
∼
A
4 (2)
∼
A
0.2 (0.1)
W
Max. 200
Wood-
chips
60
1077
1287
210
45
18
I
IP 20
Type 1 B
Non-con-
densing
0 to +35
20 to +65
−
400
50
10
1400
25
380
100
14
14
259
122
26
4 (2)
4 (2)
4 (2)
4 (2)
4 (2)
0.2 (0.1)
Max. 200
155