Commissioning the heating system
Loading the standard setting
When loading the standard setting, the control unit is
reset to factory settings.
Press the following buttons:
1.
/
for "Yes" or " No".
|
~
Setting the date
Press the following buttons:
1.
/
for the required date.
|
~
Setting the time
Press the following buttons:
1.
/
for the required time.
|
~
Selecting the cascade and boiler number
If the boiler is to be integrated in a "boiler cascade",
press the following keys:
1.
/
if not installed: "No".
|
~
If cascade installed: Boiler number "1", "2",
"3" or "4".
2.
to confirm.
d
Selecting cascade charging
Available if cascade with boiler number "1", "2", "3" or
"4" was previously selected.
Press the following keys:
1.
/
if common charging of the "Boiler cascade"
|
~
is not installed, select "No".
For common charging of the "Boiler cas-
cade", select "Screw conveyor" or "Vac-
uum module" charging.
Configuring the supply system/charging scheme
The supply system "Charging with AF flexible agitator
discharge" is set at the factory (setting "1").
Commissioning, inspection, maintenance
(cont.)
2.
to confirm.
d
2.
to confirm.
d
2.
to confirm.
d
Note
When selecting a cascade, only the following configu-
rations are available:
Boiler number 1:
Pellet store sensor
Additional boiler
Connection for heating circuits, DHW, DHW circula-
tion and solar
Boiler numbers 2, 3 or 4:
Pellet store sensor
2.
to confirm.
d