Commissioning, inspection, maintenance

Cleaning the ash chamber and ash removal

10x
3.
2.
1.
Fig. 66
Note
Ash removal cover: Weight 15.5 kg
1. Remove the ash box.
2. Remove casing panel.
84
3. Dismantle ash removal cover.
4. Clean the ash chamber with a vacuum cleaner.
5. If necessary, clean the screw conveyors with a
cleaning brush.