Emptying the ash box
Fitting the ash box
Note
Before closing the boiler, re-open the ash partition.
1.
5.
6.
B
C
Fig. 55
1. Place ash box on the platform.
2. Pull and hold pin
.
D
3. Push ash partition
E
until pin
locks home in the next hole.
D
4. Push ash box towards the boiler.
Note
The boiler can only be started when the safety
switch is pushed in and locked into place.
(cont.)
4.
in the direction of the arrow
Commissioning, inspection, maintenance
2.
D
E
3.
5. Hook in clamping clip
6. Push locking handle
.
C
into closed position.
B