Bartec APEXmv 07-37A2-2211 730 Series Operating Instructions Manual page 40

Ex p control unit
Table of Contents

Advertisement

Ex p Control unit
APEX
mv
6.2.2.3 Terminal row "X16"
Rev. 0
WARNING
RISK OF DEATH OR INJURY DUE TO UNINTENTIONAL ALTERATION OF THE
EX-RELEVANT PARAMETERS.
Explosion protection is no longer guaranteed.
 Remove the programming enable again after deliberately changing
parameters.
 After changing or adapting parameters, a subsequent functional test
must be performed.
The programming enable must be connected and activated in order to change
settings and set point values on the device.
It must only be connected during the deliberate modification of parameters.
After changing or adapting parameters, a final function test must be performed.
During normal operation of the Ex p system it may not be connected.
Terminal
Connection
1
Parameter IN
2
Parameter OUT
3
T sensor 3 IN
4
T sensor 3 OUT
5
T sensor 3 MESS
01-37A2-7D0005_MV_Manual_Exp-Control-Unit_2021005_0_en.docx
Electrical connections
The BARTEC parameter-setting switch must
be used to change the parameters.
The temperature sensor can be a PT 100 or
1000. Settings for the sensor are made in the
device. Two or three wire sensors can be
used.
Function
Contact for the parameter setting switch
Contact for the parameter setting switch
Temperature sensor connection
Temperature sensor connection
Temperature sensor connection
Page 39 of 80

Advertisement

Table of Contents
loading

Table of Contents