Bartec 07-61.1 Series Operational Instruction

Bartec 07-61.1 Series Operational Instruction

Miniature control and display unit

Advertisement

Quick Links

Operational Instruction
(Translation)
Note on instructions
When working in hazardous areas, the safety of
personnel and equipment depends on compli-
ance with the relevant safety regulations. The
people in charge of installation and mainte-
nance bear a special responsibility. It is essen-
tial that they have an exact knowledge of the
applicable rules and regulations.
The instructions provide a summary of the most
important safety measures and must be read by
everyone working with the product so that they
will be familiar with the correct handling of the
product.
The instructions have to be kept for future
reference and must be available throughout the
expected life of the product.
Description
The miniature control and display unit, type 07-
61.1-..../.... and type 07-662.-..../...., serves as
a flameproof enclosure for switching, control,
regulating and display devices in an industrial
quality. Alternatively, certified intrinsically safe
or associated apparatus can be fitted too.
The miniature control and display units consist
of an enclosure with the "flameproof enclosure"
type of protection and optionally a bearing
assembly with shafts and/or a flange with
"flameproof"-certified washers.
For connection purposes, there is either a
junction box with "increased safety" type of
protection or Ex d certified cable and conductor
entries.
The miniature control and display unit can be
used in hazardous areas in Zones 1 and 2 in
accordance with the certified explosion hazard
sub-groups IIA, IIB and IIC and the temperature
class T4/T5/T6, as well as in Zones 21 and 22
in accordance with the certified max. surface
temperature (see type label).
If the miniature control and display units contain
intrinsically safe circuits or Ex i components, the
electrical limits that are decisive for "intrinsic
safety" must be adhered to.
BARTEC
GmbH Max-Eyth-Straße 16
97980 Bad Mergentheim
Germany
Miniature Control and Display Unit
Type 07-61.1-..../....
Explosion protection
Maximum Ex type of protection
Depends on the installed components; ob-
serve the specifications on the type label.
ATEX/IECEx
II 2G
Ex d e [ib] IIC T6, T5
or T4 Gb
II 2(1)G Ex d e [ia Ga] IIC T6, T5
or T4 Gb
II 2G
Ex d e IIC T6 or T5 Gb
II 2D
Ex tb [ib] IIIC T80 °C or
T95 °C Db
II 2(1)D Ex tb [ia Da] IIIC T80 °C
or T95 °C Db
II 2D
Ex tb IIIC T80 °C or
T95 °C Db
0044
Certification
ATEX
EPS 14 ATEX 1 696
IECEx
IECEx EPS 14.0042
INMETRO
Ex d e [ib] IIC T6...T4 Gb
Ex d e [ia Ga] IIC T6...T4 Gb
Ex d e IIC T6...T5 Gb
Ex tb [ib] IIIC T80 °C...T95 °C Db
Ex tb [ia Da] IIIC T80 °C...T95 °C Db
Ex tb IIIC T80 °C...T95 °C Db
Certification
NCC 14.02943
TC RU C-DE.ГБ06.В.00443
Ambient temperature ranges
Depending on the installations; observe the
specifications on the type label.
-20 °C up to max. +70 °C
(-4 °F up to max. +158 °F)
Approved for Zones
1, 2 and 21, 22
Components
Follow the components manufacturer's
mounting instructions and safety instructions.
Other applicable documents
Circuit diagram
Mounting instructions/operating instruc-
tions for the installed components
Delivery note
The retention of these documents is manda-
tory.
Tel.: +49 7931 597-0
info@bartec.de
Fax: +49 7931 597-119
www.bartec.de
Technical data
Electrical data
Rated insulation voltage: max. 690 V
Rated current/installation
elements:
Power loss:
Nominal connection cross
section:
Protection class
Max. IP 66 (EN 60529)
Mechanical strength
Impact energy: max. 7 Nm
Enclosure material
Aluminium, surface bare/coated
Stainless steel
Brass, surface bare/nickel-plated
Cover closure
Cheese head screw,
ISO 4762-M4x14-A2-70 or
ISO 4762-M5x14-A2-70
Dimensions
See page 3.
Reservation Technical data subject to change without notice. Changes, errors and
misprints may not be used as a basis for any claim for damages.
max. 21 A
max. 8 W
max. 2.5 mm²
(14 AWG),
see type label
for
precise
details
EN 1/4

Advertisement

loading

Summary of Contents for Bartec 07-61.1 Series

  • Page 1 – tions for the installed components Delivery note – The retention of these documents is manda- tory. BARTEC GmbH Max-Eyth-Straße 16 Tel.: +49 7931 597-0 info@bartec.de Reservation Technical data subject to change without notice. Changes, errors and EN 1/4 97980 Bad Mergentheim Fax: +49 7931 597-119 www.bartec.de...
  • Page 2  Extensions or modifications to the minia- Note permitted and will exempt BARTEC from lia- ture control and display unit are only per- See the separate installations documentation bility for defects and any further liability.
  • Page 3 Check that the connecting terminals, Accessories, spare parts flameproof encapsulation. cable & conductor entries are secure.  The threaded gaps must be protected. See BARTEC catalogue. They must not be machined or varnished Note at any time later. Disposal In the course of maintenance particular atten- ...
  • Page 4 Miniature Control and Display Unit Operational Instruction (Translation) Type 07-61.1-…./…. BARTEC GmbH Max-Eyth-Straße 16 Tel.: +49 7931 597-0 info@bartec.de Reservation Technical data subject to change without notice. Changes, errors and EN 4/4 97980 Bad Mergentheim Fax: +49 7931 597-119 www.bartec.de misprints may not be used as a basis for any claim for damages.