Enter Setup

Check Character Verification

A check character is optional for Industrial 25 and can be added as the last character. It is a calculated value used to verify
the integrity of the data.
Disable: The scanner transmits Industrial 25 barcodes as is.
Do Not Transmit Check Character After Verification: The scanner checks the integrity of all Industrial 25 barcodes to
verify that the data complies with the check character algorithm. Barcodes passing the check will be transmitted except the
last digit, whereas those failing it will not be transmitted.
Transmit Check Character After Verification: The scanner checks the integrity of all Industrial 25 barcodes to verify that
the data complies with the check character algorithm. Barcodes passing the check will be transmitted, whereas those failing
it will not be transmitted.
** Disable
Transmit Check Character After Verification
If the Do Not Transmit Check Character After Verification option is enabled, Industrial 25 barcodes with
a length that is less than the configured minimum length after having the check character excluded will not
be decoded. (For example, when the Do Not Transmit Check Character After Verification option is
enabled and the minimum length is set to 4, Industrial 25 barcodes with a total length of 4 characters
including the check character cannot be read.)
** Exit Setup
Do Not Transmit Check Character After Verification
132