3.5.- OPEN WINDOW DETECTION

With open window detection activated, the heating element will be disconnected automatically when a sharp decrease in
temperature in the room is detected. Heating elements will be disconnected for 30 minutes when a decrease of 2,4ºC in less
than 4 minutes is detected. After 30 minutes, the radiator returns to the prior operation mode.
It will be shown in the displays as follows:
3.6.- OPERATION WITH WIFI G-CONTROL HUB
It is possible to control the full operation of the unit remotely with Gabarron-Elnur app or app-web. The unit must be
connected to a Wifi G-Control Hub to use this feature.
To associate the unit to the G-Control Hub, the discovery mode of the hub must be activated. With the hub in discovery mode,
press Ok/Mode key of the unit for 3 seconds.
On top right on the screen, the symbol Link will appear confirming the correct connexion between the radiator and the G-
Control Hub.
Another way to associate the unit and the G-Control Hub is press Config/Prog key and use the +/- keys to select
, when
the icon is blinking, press OK/Mode key. The unit will associate with the G-Control Hub, the symbol Link will be displayed.
To disassociate the unit, a reset of the unit must be realized. See "Unit Reset".

4. ADVANCED CONFIGURATION

To access to advanced configuration menu, press Config/Prog key in any operation mode. The next window will be displayed.
Hold Config/Prog key for 5 seconds, the first parameter(C1) will be displayed. To modify the value of the parameters, use
OK/Mode key to enter in the value of the parameter and modify the value with the keys +/-, set the modified value with the
Ok/Mode key. It is possible to exit of advanced configuration by pressing Config/Prog key at any time.
Use the same procedure to modify the others parameters, entering advanced configuration and selecting with +/- keys the
parameter to modify.