Open Window Detection; Keyboard Lock; Advanced Configuration - Gabarron DILIGENS DIL4GC Installation Instructions And User Manual

Diligens series wifi thermal radiators
Hide thumbs Also See for DILIGENS DIL4GC:
Table of Contents

Advertisement

Available languages

Available languages

EN

3.7. OPEN WINDOW DETECTION

With open window detection activated, the heating element will be disconnected automatically when a sharp decrease in
temperature in the room is detected avoiding energy wastage. After this period of time, the radiator returns to the prior
operation mode.
It will be shown in the displays as follows:
Note: To activate the window detection please refer to C5 in 3.9. ADVANCED CONFIGURATION section.

3.8. KEYBOARD LOCK

In every operation mode, it is possible to lock the keyboard by holding "+" and "-" buttons
simultaneously for 3 seconds. When the keyboard is locked, the message Lock will be displayed.
When the keyboard is locked, if any button is pressed, the display will show "Lock" and the unit will
not respond.
To unlock the keyboard, press the "+" and "-" buttons simultaneously for 3 seconds.

3.9. ADVANCED CONFIGURATION

3.9.1 To access to advanced configuration menu,
Press & Release Config/Prog button until the
follow is displayed:
Use the same procedure to modify the others parameters where necessary. It is possible to exit of advanced configuration by
pressing the Config/Prog button at any time.
Parameters
C1. Fahrenheit or Celsius Degrees.
-
The LCD displays the temperature unit selected: ºC or ºF.
C2. Control Adjustment.
-
The kind of temperature control can be modified with this parameter:
PID, Hysteresis 0,25ºC, Hysteresis 0,35ºC, Hysteresis 0,50ºC, Hysteresis 0,75ºC.
C3. Correction of ambient temperature measures.
-
If there is a difference between an external thermometer and the temperature displayed by the unit, with C3
parameter it is possible to influence on the sensor in order to balance the difference. (-3ºC to +3ºC in 0,1 steps).
C4. Firmware version.
-
Information about the current firmware version of the unit.
C5. Open Window Activation
-
ON/OFF. With the parameter in ON, the open window detection is activated.
3.9.2 Hold the Config/Prog button for 5 seconds, the first parameter
(C1) will be displayed. To select the next parameter, press the "+"
button.
16
To modify the value of the parameters,
press the OK/Mode button. Then use the
"+" and "-" buttons to select the different
options. Press the Ok/Mode button again
to set the value.