SMA POWER REDUCER BOX User Manual page 35

Hide thumbs Also See for POWER REDUCER BOX:
Table of Contents

Advertisement

SMA Solar Technology AG
Assigning Static Network Settings
For delivery, the static network settings of the Power Reducer Box are set to the following values:
IP address:
Subnet mask:
Http port:
Forwarding port
SSL port
1. Register as "Installer" on the home page of the Power Reducer Box (see Section 9.1 "Logging In
or Out of the Power Reducer Box", page 47).
☑ The "Plant overview" page opens.
2. Select [Network and system settings] in the main menu.
3. Enter the following settings in "Network settings":
• In the "Obtain IP address" field, select the "static" field (default setting).
Allocating IP addresses
Each IP address may only appear once in the local network. The IP address may never
end in 0 or 255.
• In the "IP address" field, enter the IP address under which the Power Reducer Box is to be
accessed.
• In the "Subnet mask" field enter the subnet mask of your network. This mask limits the Ethernet
network to certain IP addresses and separates the network areas from one another.
• In the "Gateway address" field, enter the gateway address of your network. The gateway
address is the IP address of the device that creates the connection to the Internet. Usually,
the address of the router is entered here.
• In the "DNS server address" field, enter the address of the DNS server. The DNS server
(Domain Name System) translates important Internet addresses (e.g.
www.sunnyportal.com) into the respective IP addresses. Type in the DNS server address that
your Internet service provider has given you or, alternatively, enter the IP address of your
router.
4. Select [Save].
☑ The static network settings have been set.
User Manual
192.168.0.200
255.255.255.0
80
80
443
8  Commissioning
REDUCERBOX-BA-en-16
35

Advertisement

Table of Contents
loading

Table of Contents