- select LANGUAGE: ENGLISH
- setting TIME and DATE
12
- setting the operating mode of the REC10CH:
MASTER: select this option when the REC10CH is also a MACHINE INTERFACE.
- configuration selection:
MAIN PCB: to reset the current boiler configuration on REC10CH MASTER and finish
the operation
NEW: to set a new system configuration restoring the factory setting of the parameters
Whenever a "NEW" configuration is selected, proceed as follows:
- select:
ON BOARD: if the REC10CH is used only as a system interface and not as an ambient
regulator
AMBIENT: if the REC10CH is used as a system interface and also as an ambient
regulator of the zone where it is installed
WHERE IS THE MULTI ZONE INSTALLED?
- select the type of boiler on:
- ONLY HEATING: if the boiler does not manage the domestic hot water (case A)
- WATER TANK: if the boiler manages a domestic hot water tank. Note: in this case the
specific type of domestic hot water request will be requested THERMOSTAT (case B) or
TEMPERATURE PROBE (case C)
- if the water tank with probe is selected you are also asked whether to manage also the
solar heating system: answer No to this question.
INSTANTANEOUS
SELECT THE PLANT CONFIGURATION
Once the guided procedure has finished, the REC10CH will go to the initial screen.
Then proceed with the reprogramming of the boiler, carrying out the operations described
in the section "4.2 Programming the boiler".
4.21
Boiler configuration
The BOILER menu allows you to change the hydraulic configuration without necessarily
having to go through a SYSTEM RESET operation.The HYDRAULIC CONFIG parameter can
assume values between 0 and 4 with the following meaning:
0 = only heating boiler
1 = instantaneous boiler with flowswitch
2 = instantaneous boiler with flowmeter
3 = only heating boiler with water tank with probe
4 = only heating boiler with water tank with thermostat
4.22
Replacing the REC10CH Master
b
The system configuration operations need to be carried out by professionally
qualified personnel of the Technical Assistance Centre.
When replacing the REC10CH MASTER, at the subsequent restart it displays an initial
screen with the firmware revision. Pressing "OK" starts a guided procedure for configuring
the system, see the section "Configuring the system".
Follow the procedure and carry out the MAIN PCB type of configuration.
REC10REXPH-N
Rxx.xx
PRESS ANY KEY TO CONTINUE
TIME & DATE
ENTER TIME AND DATE
:
17
09/04/2021
SELECT THE TYPE OF
CONFIGURATION
MAIN PCB
NEW
BOILER
ON BOARD
AMBIENT
PLANT
PLANT
CH ONLY
CH ONLY
INSTANTANEOUS
HW TANK
STORAGE TANK
SELECT THE PLANT
CONFIGURATION
SELECT THE TYPE OF
CONFIGURATION
MAIN PCB
NEW
4.23
Replacing the MAIN PCB board
The system configuration operations need to be carried out by professionally qualified
personnel of the Technical Assistance Centre. The systems continually carries out a
consistency control between the configuration data saved on the MAIN PCB electronic board
and that saved in the REC; therefore, when replacing the MAIN PCB electronic board, it might
happen that the system detects an inconsistency between the data saved on the MAIN PCB
and that in the REC. In this case, the latter will ask the user which of the two configurations is to
be considered valid; selecting to recuperate the configuration from the REC itself it is possible
to avoid reconfiguring the machine:
- select REC10CH.
4.24
Combustion Control Parameters
Even if the parameters regarding the new ACC combustion control system (active
combustion control) are preset in the factory, it might be necessary to programme them, this
is in the case where both electronic boards (MAIN PCB and REC10CH MASTER) need to
be replaced at the same time.
- set SERVICE password
- select TECHNICAL
COMBUSTION MONITORING
AIR PURGING CYCLE
EXHAUST PROBE RESET
COMBUSTION MONITORING
SERVICE
- select GAS TYPE
- set depending on the type of gas of the boiler: MTN = METHANE - GPL = LPG
COMBUSTION MONITORING
COMBUSTION OFFSET
SERVICE
- select BOILER TYPE and schedule as shown in the table
SERVICE
Exclusive X 25R
Exclusive X 35R
Exclusive X 40R
- select COMBUSTION OFFSET
COMBUSTION OFFSET
SERVICE
RESTORE: select this option when replacing the MAIN PCB electronic board
RESET: select this option when replacing the detector electrode.
b
If after maintenance work on the elements of the combustion unit (Repositioning
the detector electrode or else replacing/cleaning the primary heat exchanger,
condensate siphon, fan, burner, flue gases conveyor, gas valve, gas valve
diaphragm), the boiler generates one or more alarms regarding combustion faults,
we recommend setting the main system switch to off for at least 5 minutes in these
cases we recommend setting the main system switch to off for at least 5 minutes.
SELECT THE TYPE OF
CONFIGURATION
MAIN PCB
REC10
TECHNICAL
PARAMETERS
ERROR HISTORY
GAS TYPE

BOILER TYPE

BOILER TYPE
A
B
C
...
BOILER TYPE
A
G
H
RESTORE
RESET
ENGLISH
EN
19