Advertisement

4.14
Lights and faults
The occurrence of an anomaly is indicated by the presence of the
main screen.
FRI
18/05/2013
MENU
INFO
HOT WATER TEMPERATURE
Move inside the display until the
icon is highlighted. The error message will be displayed.
The faults description screen is automatically displayed once the display illumination time
has elapsed without any button being pressed.
Reset function
To restore boiler operation, press "OK" from the error message screen. At this point, if the
correct operating conditions have been restored, the boiler will restart automatically. There
are a maximum of 3 consecutive attempts at a release by the REC10CH. In case of all the
attempts are exhausted the definitive fault E099 occurs on the display. The boiler will need
to be unlock by cutting off and reconnecting the electrical supply.
LIMIT THERMOSTAT
RESET ATT. EXHAUSTED
b
If the reset attempts do not activate the boiler, contact the Technical Assistance
Centre.
if the pressure drops below the safety threshold of 0.3 bar the boiler displays
For fault E041:
the fault code "E041 - WATER TRANSDUCER FILL THE SYSTEM" for a transitional time of
30 sec during which it is possible to open the external filling tap until the pressure is between
1 and 1.5 bar.
E041
WATER TRANSDUCER
PRESS OK FOR AUTO FILL
b
If the drop in pressure is very frequent, contact the Technical Assistance Centre.
Boiler faults list
ERROR CODE
E010
E011
E020
E030
E040
E041
E042
E060
E070
E077
E080
E090
E091
E099
--
--
--
--
flashing icon on the
PLANT
12:17
bar
STATE
1.3
42
°C
SET
E020
ERROR MESSAGE
flame lockout/ACF electronic fault
extraneous flame
limit thermostat
water transducer – fill the system
water transducer – fill the system
water pressure transducer fault
water tank probe fault
flow sensor faulty
flow sensor overtemperature
flow/return sensor differential alarm
main zone water thermostat
return line probe fault
return line probe overtemperature
outlet/return line probe differential alarm
flue gas probe faulty
flue gas probe overtemperature
clean primary heat exchanger
reset attempts exhausted, boiler blocked
water pressure low - check system
water pressure high - check system
boiler board communication lost
BUS 485 communication lost
For fault E060: the appearance of this error, on only heating models with water tank with
probe connected, prevents DHW operation.
For fault E091: the boiler has an auto-diagnostic system which, based on the total number
of hours in certain operating conditions, can signal the need to clean the primary exchanger
(alarm code E091). Once the cleaning operation has been completed, reset to zero the total
hour meter with special kit supplied as an accessory following procedure indicated below:
- select TECHNICAL
TECHNICAL
WEATHER COMPENSATION
RANGE RATED
CALIBRATION
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
INSTALLER
Note: The meter resetting procedure should be carried out after each in-depth cleaning of
the primary exchanger or if this latter is replaced.
The total hours can be verified in the following way: INFO menu
press "OK" to display the value of the flue gases probe meter
fan fault
EXHAUST PROBE RESET
THE PARAMETER WILL BE
CONFIRM
CONFIRM OR DELETE SELECTION
FRI
PLANT
18/05/2013
12:17
bar
MENU
STATE
1.3
30
°C
.3
INFO
SET
HOT WATER TEMPERATURE
DESCRIPTION OF TYPE OF ALARM
definitive, not resettable
ENGLISH
EN
CONFIRM or BACK.
CHANGED
CANCEL
FLUE GAS PROBE
definitive
transitional
definitive
definitive
definitive
transitional
definitive
transitional
transitional
definitive
definitive
transitional
transitional
definitive
definitive
transitional
definitive
transitional
transitional
transitional
transitional
transitional
17