CHECK PLUMB
Choose a wall and set laser 5m away from the wall. Mark point A on the
wall, please note the distance from point A to ground should be 3m. Hanga
plumb line from A point to ground and find a plumb point B on ground.
turn on the laser and make the vertical laser line meet the point B, along
the vertical laser line on the wall and measure the distance 3m from point
B to another point C. Point C must be on the vertical laser line, it means the
height of C point is 3m.
Measure the distance from point A to point C, if the distance is over 2mm,
please, contact with seller to calibrate the laser.

PRODUCT LIFE

Product life of the tool is 7 years. The battery and the tool should never
be placed in municipal waste. Date of production, manufacturer's contact
information, country of origin are indicated on the product sticker.

CARE AND CLEANING

Please handle line laser with care. Clean with soft cloth only after any use.
If necessary damp cloth with some water. If instrument is wet clean and
dry it carefully. Pack it up only if it is perfectly dry. Transport in original
container/case only.

SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS

• Measurements through glass or plastic windows;
• Dirty laser emitting window;
• After line laser has been dropped or hit. Please check the accuracy;
• Large fluctuation of temperature: if instrument will beused in cold areas
after it has been stored in warm areas (or the other way round) please wait
some minutes before carrying out measurements.