Troubleshooting - Orlanski ORLIGNO 100 Manual And Service Manual

Table of Contents

Advertisement

7. Troubleshooting

Type of defect
One of controller's
Display malfunction
button doesn't
work
Automatic lightning
Wrong connection of igniter or
up Doesn't work
photo-cell
Clogged outlet hole of hot air
Very damp fuel
Damaged igniter
Damaged photo-cell
Smoke from door
Lack of chimney draft
or burner
Clogged chimney
Clogged heat exchanger
Damaged sealant (rope)
Water in boiler
Lack of chimney draft
Very damp fuel
Leaky heat exchanger
Boiler cannot reach
Improperly selected boiler for
set temperature
heating space
Wrongly located sensor of return
water
Sensor malfunction
Set low boiler power
Possible cause of defect
Suggested repair
Display repair
Check plug and wires connections of igniter and
photo-cell
Clean heater hole
Change or dry fuel
Replace igniter
Replace photo-cell
Clean heat exchanger
Replace sealant (rope)
Improper chimney installation
Change or dry fuel
To check heat exchanger, turn off boiler on 8 hours,
remove water, when water is still in boiler – call
service
Check if boiler is properly selected
Check sensor location
Check sensors
Check feed time and fan power
27

Advertisement

Table of Contents
loading

Table of Contents