14.3. Settings
Description of functions in submenu SETTINGS
Function
Comfort temperature
Program
Heat now
Hysteresis
Economic temperature
14.4. Time program
It is for time program configuration of h.d.w.
Settings description of time program can be found in chapter 3.4
14.5. Service
ATTENTION!
Service menu is only for qualified staff. Any settings' changes may lead to incorrect
system operation.
Description of functions in submenu SERVICE:
Function
Source delta
Source
Max. temperature
Delta MIN temp.
Pump test
Circuit name
Programmed temperature of h.d.w. during heating period
Programs:
a. time program – according to programmed time- intervals
b. permanent – no matter of time-intervals comfort
temperature is kept
c. off – heating is turned off
Heats once h.d.w. up to comfort temperature regardless of
program
Decrease of temperature value for h.d.w.
Programmed h.d.w. temperature after heating period.
Source temperature increase in relation to programmed
h.d.w temperature during heating.
Determines source of energy for h.d.w.
Maximal h.d.w. temperature
Minimal temperature difference between source and h.d.w,
at which pumps work
Starts pump regardless of other conditions.
Gives the name for h.d.w. circuit
Description
Description
39