20. Electric installation

20.1. Overall requirements
Before use of this controller; it is necessary to thoroughly read instruction manual.
Person responsible for controller's installation should have technical experience. Connections
made of copper should be adjusted to operate at temperatures of 75°C.
All electric connections should comply with electric scheme enclosed in this manual and national
or local rules concerning electric installations
ATTENTION!
Appliance should be connected to separate electric circuit equipped with properly
selected RCD (residual current device) and MCB ( miniature circuit breaker).
20.2. Location
Appliance is intended for use in confined premises.
Assembly location must be free from dampness and inflammable, fumes that cause corrosion.
Appliance assembly cannot be done close to any high-power, appliances, industrial equipment or
welding equipment.
Ambient temperature around assembly place cannot exceed 60°C and should not be lower than
0°C. Humidity should be in range 5-95%.
20.3. Connection
It is necessary to connect to boiler sensor and other executiue elements if needed. Picture shows
connection diagram of appliances table shows description of inputs and outputs.
ATTENTION!
It is not allowed to connect (PE) safety wire with zero(N).