5. Putting into operation

5.1. Burner start

First startup of the burner must be done by authorized company trained by manufacturer with valid
certificate of authorized serviceman issued by Eko-Vimar Orlanski ltd.

5.2. Burner's assembly to ORLIGNO 100

1. Remove the screws (1) fastened to burner's casing (pic.4) and take off casing (2)
2. Take off ORLIGNO 100 bottom door
3. Fix adapter (3) in bottom's door place (pic.5)
4. Fix burner (4) in adapter (3) screwing it with two bolts (5)
5. Mount burner's casing (2) with two screws (1)
6. Slide feeder's pipe (6) in to fixing pipe (7) (pic.6)
7. Fit flexible pipe (8) on feeder's pipe (6) and secure with band clip (9)
8. Fit flexible pipe (8) on burner's pipe (10) and secure with band clip (9)

5.3. Adjustment of ORLIGNO 100 to work with pellet burner

1. Remove iron-cast grate from boiler.
2. Place two refractory bricks on each of two supports above support for iron-cast grate.
Pic.4. Disassembly of burner's casing.